Measurement of respiratory muscles strength such as maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) are used to detect, diagnose and treat respiratory weakness. However, devices used for these measurements are not widely available and are costly. Currently, the use of a digital manometer is recommended. In industry, several inexpensive devices are available, but these have not been validated for clinical use. Our objective was to determine the agreement between maximal respiratory pressures obtained with a clinical digital manometer and that with a non-clinical digital manometer in healthy volunteers. We assessed the height, weight, lung function, MIP, and MEP of healthy volunteers. To compare pressures obtained by each type of digital manometer, a parallel approach configuration was used. The agreement was measured with the Intraclass Coefficient Correlation (ICC) and the Bland-Altman plot. Twenty-seven participants (14 men) were recruited with a median age of 22 (range: 21-23) years. Each participant underwent three measurements to give a total of 81 measurements. The mean MIPs were 90.8 ± 26.4 (SEM 2.9) and 91.1 ± 26.4 (SEM 2.9) cmH2O for the clinical and non-clinical digital manometers, respectively. The mean MEPs were 113.8 ± 40.4 (SEM 4.5) and 114.5 ± 40.5 (SEM 4.5) cmH2O for the clinical and non-clinical digital manometers, respectively. We obtained an ICC of 0.998 (IC 0.997-0.999) for MIP and 0.999 (IC 0.998-0.999) for MEP. There is a high agreement in the values obtained for MIP and MEP between clinical and non-clinical digital manometers in healthy volunteers. Further validation at lower pressures and safety profiling among human subjects is needed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6812781PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0224357PLOS

Publication Analysis

Top Keywords

non-clinical digital
20
digital manometer
20
clinical non-clinical
16
healthy volunteers
12
digital manometers
12
digital
8
maximal respiratory
8
respiratory pressures
8
mip mep
8
264 sem
8

Similar Publications

Validation of the Spanish version of the Adjustment Disorder New Module-20 (ADNM-20) in a non-clinical sample.

BMC Psychol

December 2024

Department of Clinical, Neuro and Developmental Psychology, Amsterdam Public Health Research Institute, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands.

Background: There is a lack of self-report measures specifically designed for Adjustment disorder. One of the most widely used instruments is the Adjustment Disorder New Module (ADNM), which has already been validated in different countries. The aim of this study was to validate the Spanish version of the ADNM-20 with a non-clinical sample, including a comparison with a high-risk sample.

View Article and Find Full Text PDF

Background: Building research capacity can strengthen health systems through evidence-based interventions. However, evaluating the current research capacity and increasing it is a layered process that needs to consider different institutional structures, as well as internal factors. This study collects baseline data on the research capacity and culture at King Faisal Hospital Rwanda (KFH), a tertiary-level teaching hospital in Rwanda.

View Article and Find Full Text PDF
Article Synopsis
  • Intra and inter-pathologist variability complicates the evaluation of metabolic dysfunction-associated steatohepatitis (MASH) biopsy results, hindering patient selection and assessment quality in clinical trials.
  • A study analyzed 120 histology slides with and without AI assistance to evaluate its impact on pathologists' reliability in fibrosis staging, especially for early fibrosis stages.
  • Results showed that AI assistance significantly improved concordance among pathologists, increasing agreement rates for clinical trial inclusion and exclusion, which could enhance the overall efficiency and reliability of MASH-related clinical research.
View Article and Find Full Text PDF

Background And Aims: Hepatorenal syndrome - Acute Kidney Injury (HRS-AKI) is a severe complication of decompensated cirrhosis that is challenging to predict. Sentiment analysis, a computational process of identifying and categorizing opinions and judgment expressed in text, may enhance traditional prediction methodologies based on structured variables. Large language models (LLMs), such as generative pretrained transformers (GPTs), have demonstrated abilities to perform sentiment analyses on non-clinical texts.

View Article and Find Full Text PDF

Prefrontal cortex activation and working memory performance in individuals with non-clinical depression: Insights from fNIRS.

Acta Psychol (Amst)

November 2024

Dept. of Occupational Therapy, College of Software and Digital Healthcare Convergence, Yonsei University, South Korea. Electronic address:

Previous research has extensively explored cognitive and neural deficits in clinically diagnosed depression, but the early stages of depression, where symptoms do not meet clinical thresholds, are less explored. This study investigated neurocognitive markers in individuals with non-clinical depression. The study assessed working memory (WM) performance and hemodynamic responses of prefrontal cortex (PFC) in 30 individuals with non-clinical depression and 41 healthy controls using two-back tasks with four stimulus types: numbers, letters, shapes, and emotional facial expressions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!