Dilatometric strain sensors (DSS) that work based on detection of volume change in microfluidic channels; i) are highly sensitive to biaxial strain, ii) can be fabricated using only soft and transparent materials, and iii) are easy to integrate with smart-phones. These features are especially attractive for contact lens based intraocular pressure (IOP) sensing applications. The inherent flow stabilization of the microfluidic systems is an additional advantage suitable for filtering out rapid fluctuations. Here, we have demonstrated that the low-pass filtering in microfluidic sensors improves the signal-to-noise-ratio for ophthalmic applications. We have fabricated devices with a time constant in the range of 1-200 seconds. We have demonstrated that the device architecture and working liquid viscosity (10-866 cSt) are the two independent factors that determine the sensor time constant. We have developed an equivalent circuit model for the DSS that accurately represents the experimental results thus can be used as a computational model for design and development of microfluidic sensors. For a sensor with the time constant of 4 s, we report that microfluidic signal filtering in IOP monitoring applications can suppress the rapid fluctuations (i.e., the noise due to ocular pulsation, blinking etc.) by 9 dB without the need for electronic components.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c9lc00842jDOI Listing

Publication Analysis

Top Keywords

microfluidic sensors
12
time constant
12
flow stabilization
8
rapid fluctuations
8
sensor time
8
microfluidic
6
stabilization wearable
4
wearable microfluidic
4
sensors
4
sensors enables
4

Similar Publications

The application of physical fields is crucial for droplet generation and manipulation, underpinning technologies like printing, microfluidic biochips, drug delivery, and flexible sensors. Despite advancements, precise micro/nanoscale droplet generation and accurate microfluidic reactions remain challenging. Inspired by the liquid ejection mechanisms in microscopic organisms, an electrostatic manipulator for the precise capture, emission, and transport of microdroplets is proposed.

View Article and Find Full Text PDF

Advances in the design and application of contactless conductivity detectors for separation, flow-through, microfluidic and sensing techniques: A review.

Anal Chim Acta

February 2025

Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00, Prague 10, Czech Republic. Electronic address:

The review focuses on the design of detection cells, the use of microcontrollers for processing and evaluation of the detection signal, and the development of multi-detection systems for electromigration, liquid chromatography, flow-through and microfluidic techniques. A separate section is the introduction of modern 3D printing techniques and the use of new printing materials for the design of multidetection systems. In addition to traditional utilisation in separation techniques, new versions of contactless conductivity detectors are finding applications in FIA, SIA, portable and paper based analytical systems or as independent sensors.

View Article and Find Full Text PDF

Modeling of Electric Field and Dielectrophoretic Force in a Parallel-Plate Cell Separation Device with an Electrode Lid and Analytical Formulation Using Fourier Series.

Sensors (Basel)

December 2024

Department of Applied Physics, National Defense Academy, Hashirimizu 1-10-20, Yokosuka 239-0802, Kanagawa, Japan.

Dielectrophoresis (DEP) cell separation technology is an effective means of separating target cells which are only marginally present in a wide variety of cells. To develop highly efficient cell separation devices, detailed analysis of the nonuniform electric field's intensity distribution within the device is needed, as it affects separation performance. Here we analytically expressed the distributions of the electric field and DEP force in a parallel-plate cell separation DEP device by employing electrostatic analysis through the Fourier series method.

View Article and Find Full Text PDF

Time-resolved single-cell secretion analysis microfluidics.

Lab Chip

January 2025

Department of Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon Tong, Hong Kong, China.

Revealing how individual cells alter their secretions over time is crucial for understanding their responses to environmental changes. Key questions include: When do cells modify their functions and states? What transitions occur? Insights into the kinetic secretion trajectories of various cell types are essential for unraveling complex biological systems. This review highlights seven microfluidic technologies for time-resolved single-cell secretion analysis: 1.

View Article and Find Full Text PDF

Review of advances in glycan analysis on exosomes, cancer cells, and circulating cancer-derived glycoproteins with an emphasis on electrochemistry.

Anal Chim Acta

January 2025

Department of Biomedical Engineering, Korea University, Seoul, 02841, South Korea; Interdisciplinary Program in Precision Public Health, Korea University, Seoul, 02841, South Korea. Electronic address:

Glycosylation, the intricate process of adding carbohydrate motifs to proteins, lipids, and exosomes on the cell surface, is crucial for both physiological and pathological mechanisms. Alterations in glycans significantly affect cancer cell metastasis by mediating cell-cell and cell-matrix interactions. The subtle changes in glycosylation during malignant transformations highlight the importance of analyzing cell and exosome surface glycosylation for prognostic and early treatment strategies in cancer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!