Real-time impedimetric droplet measurement (iDM).

Lab Chip

Institute of Materials Science and Nanotechnology, National Nanotechnology Research Center (UNAM), Bilkent University, Ankara 06800, Turkey.

Published: November 2019

AI Article Synopsis

  • Droplet-based microfluidic systems need precise control over droplet properties for effective analysis, making morphological measurement crucial.
  • Researchers developed a method using coplanar electrodes for real-time measurement of droplet size and velocity through advanced simulations and electric field interactions.
  • They created user-friendly software for live observation and statistical analysis, compared measurement techniques, and evaluated the warm-up time for droplet generators to ensure consistent droplet size for applications.

Article Abstract

Droplet-based microfluidic systems require a precise control of droplet physical properties; hence, measuring the morphological properties of droplets is critical to obtain high sensitivity analysis. The ability to perform such measurements in real-time is another demand which has not been addressed yet. In this study, we used coplanar electrodes configured in the differential measurement mode for impedimetric measurement of size and velocity. To obtain the size of the droplets, detailed 3D finite element simulations of the system were performed. The interaction of the non-uniform electric field and the droplet was investigated. Electrode geometry optimization steps were described and design guideline rules were laid out. User-friendly software was developed for real-time observation of droplet length and velocity together with in situ statistical analysis results. A comparison between impedimetric and optical measurement tools is given. Finally, to illustrate the benefit of having real-time analysis, iDM was used to synthesize particles with a predefined monodispersity limit and to study the response times of syringe pump and pressure pump driven droplet generation devices. This analysis allows one to evaluate the 'warm-up' time for a droplet generator system, after which droplets reach the desired steady-state size required by the application of interest.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c9lc00641aDOI Listing

Publication Analysis

Top Keywords

droplet
6
real-time
4
real-time impedimetric
4
impedimetric droplet
4
measurement
4
droplet measurement
4
measurement idm
4
idm droplet-based
4
droplet-based microfluidic
4
microfluidic systems
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!