Determining current carrying capacity (ampacity) of wire bundles in aerospace vehicles is critical not only to safety but also to efficient design. Published standards provide guidance on determining wire bundle ampacity but offer little flexibility for configurations where wire bundles of mixed gauges and currents are employed with various external insulation jacket surface properties. Thermal modeling has been employed in an attempt to develop techniques to assist in ampacity determination for these complex configurations. An earlier tool allowed analysis of wire bundle configurations but was constrained to configurations comprised of less than 50 elements. Additionally, for vacuum analyses, configurations with very low emittance external jackets suffered from numerical instability in the solution. A new thermal modeler is presented allowing for larger configurations and is not constrained by low bundle jacket surface infrared emittance calculations. Formulation of key internal radiation and interface conductance parameters is discussed including the effects of temperature and ambient air pressure on wire-to-wire thermal conductance. Test cases comparing model-predicted ampacity and that calculated from standards documents are presented.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6800675 | PMC |
http://dx.doi.org/10.11159/jffhmt.2017.006 | DOI Listing |
Cureus
October 2024
Cardiology, Doncaster and Bassetlaw Teaching Hospitals NHS Foundation Trust, Doncaster, GBR.
Inadvertent lead malposition (ILM) of a temporary pacing wire is a rare complication that can occur during pacemaker insertion. We report a case of a 40-year-old man who presented late following an inferior ST segment elevation myocardial infarction. Temporary cardiac pacing was performed for symptomatic complete heart block.
View Article and Find Full Text PDFCureus
October 2024
Department of Cardiology and Nephrology, Mie University Graduate School of Medicine, Tsu, JPN.
Right bundle branch block can occasionally occur when a guide wire or catheter is inserted into the heart. An 83-year-old woman with preexisting left bundle branch block (LBBB) was diagnosed with paroxysmal atrial fibrillation (PAF) and severe mitral regurgitation (MR). The patient was started on amiodarone (100 mg/day) and bisoprolol (1.
View Article and Find Full Text PDFSci Rep
November 2024
Department of Materials Engineering, Ming Chi University of Technology, R.O.C, New Taipei, 243303, Taiwan.
JBJS Essent Surg Tech
October 2024
Department of Orthopaedic Surgery, Lok Nayak Hospital, Maulana Azad Medical College, New Delhi, India.
Background: Severe elbow deformities are common in developing countries because of neglect or as a result of prior treatment that achieved poor reduction. Various osteotomy techniques have been defined for the surgical correction of elbow deformities. However, severe elbow deformities (>30°) pose a substantial challenge for surgeons because limited surgical options with high complication rates have been described in the literature.
View Article and Find Full Text PDFSci Total Environ
December 2024
The Illinois Sustainable Technology Center, Prairie Research Institute, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
Disposable e-cigarettes (vapes) are becoming increasingly popular but there are concerns about their impacts on human health, the environment and resource sustainability. A better understanding of these impacts and potential solutions requires characterisation and quantification of the materials and chemicals used in their construction. In the present study we dismantle nine types of popular, single-use vapes and analyse the components by X-ray fluorescence spectrometry and pyrolysis-gas chromatography mass spectrometry.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!