Solid-state nanopores are an emerging biosensor for nucleic acid and protein characterization. For use in a clinical setting, solid-state nanopore sensing requires sample preparation and purification, fluid handling, a heating element, electrical noise insulators, and an electrical readout detector, all of which hamper its translation to a point-of-care diagnostic device. A stand-alone microfluidic-based nanopore device is described that combines a bioassay reaction/purification chamber with a solid-state nanopore sensor. The microfluidic device is composed of the high-temperature/solvent resistance Zeonex plastic, formed via micro-machining and heat bonding, enabling the use of both a heat regulator and a magnetic controller. Fluid control through the microfluidic channels and chambers is controlled via fluid port selector valves and allows up-to eight different solutions. Electrical noise measurements and DNA translocation experiments demonstrate the integrity of the device, with performance comparable to a conventional stand-alone nanopore setup. However, the microfluidic-nanopore setup is superior in terms of ease of use. To showcase the utility of the device, single molecule detection of a DNA PCR product, after magnetic bead DNA separation, is accomplished on chip.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6800661PMC
http://dx.doi.org/10.1002/adfm.201804182DOI Listing

Publication Analysis

Top Keywords

chamber solid-state
8
solid-state nanopore
8
electrical noise
8
device
5
solid-state
4
solid-state hard
4
hard microfluidic-nanopore
4
microfluidic-nanopore biosensor
4
biosensor multilayer
4
multilayer fluidics
4

Similar Publications

Solid-State Photoluminescence of Diphenylnaphthalenes Studied by Photophysical Measurements and Crystallographic Analysis.

Molecules

December 2024

Department of Chemistry, Faculty of Environment, Life, Natural Sciences and Technology, Okayama University, Okayama 700-8530, Japan.

Thanks to recent developments in spectrophotometric instruments, the spectra, quantum yields (Φ), and lifetimes () of photoluminescence from organic and inorganic compounds can be readily determined not only in solution but also in the solid state. It is known that naphthalene emits fluorescence in solution, but not in the solid state. In a previous paper, we reported that solid-state emission can be seen from biaryl compounds comprised of chromophores that show no emission in the solid state.

View Article and Find Full Text PDF

On the correction factors for small field dosimetry in 1.5T MR-linacs.

Phys Med Biol

January 2025

Medical Physics Laboratory, School of Medicine, National and Kapodistrian University of Athens, 75 Mikras Asias, Goudi, Athens, Attica, 11527, GREECE.

Clinical dosimetry in the presence of a 1.5T magnetic field is challenging, let alone in case small fields are involved. The scope of this study is to determine a set of relevant correction factors for a variety of MR-compatible detectors with emphasis on small fields.

View Article and Find Full Text PDF

Nd:YAG Laser Application for the Treatment of Retained Lens Fragment in the Anterior Chamber Following Cataract Surgery.

Turk J Ophthalmol

December 2024

University of Health Sciences Türkiye, Ulucanlar Eye Training and Research Hospital, Clinic of Ophthalmology, Ankara, Türkiye.

Cataract surgery is the most frequently performed surgery worldwide. Although it is an effective surgical treatment option for improving patients' visual acuity, various complications can occur postoperatively. One such complication is the presence of retained lens material in the anterior chamber, which can lead to intraocular inflammation, increased intraocular pressure, corneal edema, and endothelial cell loss.

View Article and Find Full Text PDF

For many synchrotron radiation experiments, it is critical to perform continuous, real-time monitoring of the X-ray flux for normalization and stabilization purposes. Traditional transmission-mode monitors included metal mesh foils and ionization chambers, which suffered from low signal stability and size constraints. Solid-state detectors are now considered superior alternatives for many applications, offering appealing features like compactness and signal stability.

View Article and Find Full Text PDF
Article Synopsis
  • * The issues were caused by brownish pigments accumulating in the eye, likely moving from the trabecular meshwork through a previous surgical opening, despite conservative treatments like topical steroids not providing relief.
  • * A successful follow-up procedure using a special laser technique helped to disperse the pigments and relieve the patient's symptoms, highlighting the need for awareness and management of this complication, as well as suggesting a preventative measure.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!