A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Long-term clinical outcomes of Amplatzer cardiac plug versus Amulet occluders for left atrial appendage closure. | LitMetric

Objectives: To compare long-term clinical outcomes after left atrial appendage closure with the Amplatzer Cardiac Plug (ACP) and Amulet.

Background: The Amulet was designed to improve clinical outcomes of first-generation ACP.

Methods: Three Amplatzer registries (Bern, Coburg, Zurich), with enrollment of patients from 2009 to 2018, were retrospectively analyzed. The primary safety endpoint was a composite of major peri-procedural complications and major bleedings, the primary efficacy endpoint included stroke, systemic embolism, and cardiovascular/unexplained death. The net clinical benefit was a combination of all above-mentioned hazards.

Results: A total of consecutive 563 patients (344 ACP vs. 219 Amulet) with a mean follow-up of 2.9 ± 1.6 and 1.9 ± 0.9 years were included. Mean age (74.4 ± 9.9 [ACP] vs. 74.4 ± 9.1 [Amulet] years), stroke (CHA DS -VASc score 4.4 ± 1.6 vs. 4.6 ± 1.7), and bleeding risk (HAS-BLED score 3.2 ± 1.1 vs. 3.2 ± 0.9) were comparable. The primary endpoints of efficacy (72/998, 7.2% [ACP] vs. 43/417, 10.3% [Amulet]; hazard ratio [HR], 0.67; 95% confidence interval [CI], 0.44-1.02, p = .062), safety (40/998, 4.0% vs. 18/417, 4.3%; HR, 1.15; 95% CI, 0.53-2.51, p = .72), and the net clinical benefit (101/998, 10.1% vs. 55/417, 13.4%; HR, 0.73; 95% CI, 0.49-1.07, p = .11) were similar.

Conclusion: In the long term, left atrial appendage closure with first and second-generation Amplatzer devices provided similar efficacy, safety, and net clinical benefit. Clinical outcomes may be rather determined by implantation technique and hemodynamics, but not by the design modifications of the Amulet.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.28530DOI Listing

Publication Analysis

Top Keywords

clinical outcomes
16
left atrial
12
atrial appendage
12
appendage closure
12
net clinical
12
clinical benefit
12
long-term clinical
8
amplatzer cardiac
8
cardiac plug
8
clinical
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!