The use of conventional implantable cardioverter-defibrillators (ICDs) in children presents important technical challenges. We present the surgical technique necessary to adapt the subcutaneous ICD (S-ICD) implantation designed for adults, to children, including patients weighing less than 20 kg. The implant procedure implies a two-incision technique and interfascial serratus anterior-latissimus dorsi dissection to accommodate the device. S-ICD implantation was successfully performed in three patients of 19, 28, and 24 kg, respectively, two of them suffered cardiorespiratory arrest. Intermuscular thoracic implantation of S-ICD might represent an effective strategy for primary or secondary prevention of sudden cardiac death in pediatric patients.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0039-1697914DOI Listing

Publication Analysis

Top Keywords

s-icd implantation
12
pediatric patients
8
intermuscular s-icd
4
implantation
4
implantation pediatric
4
patients
4
patients conventional
4
conventional implantable
4
implantable cardioverter-defibrillators
4
cardioverter-defibrillators icds
4

Similar Publications

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an alternative to traditional ICDs. The PRAETORIAN score, based on chest radiographs, has been validated to predict the probability of successful S-ICD defibrillation testing by assessing factors like fat thickness between the coil and sternum and generator placement.

Objective: This study evaluated the correlation between the PRAETORIAN score and clinical characteristics, as well as implantation variables.

View Article and Find Full Text PDF

Antithrombotic therapy and the risk of pocket hematoma after subcutaneous implantable cardioverter-defibrillator implantation.

J Interv Card Electrophysiol

January 2025

Heart Center, Department of Cardiology, Amsterdam Cardiovascular Sciences Heart Failure & Arrhythmias, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105, AZ, Amsterdam, the Netherlands.

Background: Little data exists regarding the optimal antithrombotic strategy during S-ICD implantation to prevent pocket hematomas. This study explores the association between perioperative antithrombotic management and the occurrence of pocket hematoma following S-ICD implantation.

Methods: All patients who underwent de novo S-ICD implantation between February 2009 and January 2023 at Amsterdam UMC were included.

View Article and Find Full Text PDF

Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.

Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.

Results: The majority of patients (87.

View Article and Find Full Text PDF

Unlabelled: New cardiac implantable electronic devices (CIEDs), such as leadless pacemakers and subcutaneous implantable cardioverter defibrillators (S-ICDs), are being used in patients with adult congenital heart disease. The selection of CIEDs often requires careful consideration due to technical challenges posed by a unique heart structure. A 27-year-old man following a surgical tetralogy of Fallot (TOF) repair developed non-sustained ventricular tachycardia, sick sinus syndrome, and complete atrioventricular block.

View Article and Find Full Text PDF

Inappropriate Therapy and Shock Rates Between the Subcutaneous and Transvenous Implantable Cardiac Defibrillator: A Secondary Analysis of the PRAETORIAN Trial.

Circ Arrhythm Electrophysiol

December 2024

Department of Cardiology, Amsterdam UMC Location University of Amsterdam, Heart Center, Amsterdam Cardiovascular Sciences Heart failure and Arrhythmias, the Netherlands (L.R.A.O.N., S.P., L.V.A.B., T.F.B., A.-F.B.E.Q., W.v.d.S., L.S., J.A.d.V., J.G.P.T., N.R.B., J.R.d.G., K.M.K., A.d.W., A.A.M.W., R.E.K.).

Article Synopsis
  • Inappropriate therapy (IAT) is a significant issue associated with implantable cardiac defibrillator (ICD) therapy, particularly highlighted in early subcutaneous ICD (S-ICD) studies which showed high rates of inappropriate shocks (IAS).
  • The PRAETORIAN trial, an international study with 849 patients, found no major differences in IAT and IAS rates between S-ICD and transvenous ICD (TV-ICD) groups, as both groups had similar cumulative incidences.
  • Key predictors for IAT varied between the two groups, with TV-ICD patients experiencing IAT mainly from supraventricular tachycardias, while S-ICD patients faced issues from cardiac oversensing
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!