Background And Aims: Second-generation colon capsule endoscopy (CCE-2) has shown promising accuracy for the diagnosis of overall neoplasia. Advanced neoplasia (AN) represents the main target of colorectal cancer screening programs. Our aim was to assess the diagnostic accuracy of CCE-2 for the detection of AN in patients with a positive result for the fecal immunochemical test (FIT) who are undergoing screening.

Methods: Patients aged 50 to 69 years with a positive result for the FIT in 4 population screening programs in Italy and Spain were enrolled. Screenees were asked to undergo CCE-2, followed by traditional colonoscopy (TC). TC was performed the same day or the following morning. Bowel preparation included a split-dose polyethylene glycol-based regimen, with sodium phosphate (NaP) with gastrografin as boosters. The CCE-2 video was read by an endoscopist blinded to the results of TC. The main outcomes were CCE-2 accuracy in terms of sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for AN when using 2 different size thresholds for TC referral (ie, polyps ≥6 mm and ≥10 mm).

Results: Two hundred twenty-two patients were enrolled, and 178 patients completed both CCE-2 and TC (87.7%). Overall, 59 cases of AN were detected at TC. CCE-2 sensitivity was 90%, specificity was 66.1%, PPV was 57.4%, and NPV was 92.9% for AN when using a 6-mm cut-off (TC referral rate, 52.8%) and 76.7%, 90.7%, 80.7%, and 88.4% when using a 10-mm cut-off (TC referral rate, 32%), respectively. CCE-2 detected that 8 of 9 already developed colorectal cancers. Among the 41 false positives at the 6-mm cut-off, 34 (82.9%) presented with a nonadvanced adenoma at TC. Mean transit time was 4 hours and 4 minutes, and ≥70% of patients excreted the capsule within 5 hours.

Conclusions: In an enriched disease setting, we showed the high sensitivity of CCE-2 for the diagnosis of AN at a 6-mm cut-off. The apparently low CCE-2 specificity is related to the choice of AN as the main outcome. (Clinical trial registration number: ISRCTN 62158762.).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.gie.2019.09.041DOI Listing

Publication Analysis

Top Keywords

6-mm cut-off
12
cce-2
10
colon capsule
8
capsule endoscopy
8
advanced neoplasia
8
screening programs
8
positive result
8
cut-off referral
8
referral rate
8
patients
5

Similar Publications

Clinical validation of a prognostic preclinical magnetic resonance imaging biomarker for radiotherapy outcome in head-and-neck cancer.

Radiother Oncol

December 2024

Section for Biomedical Physics, Department of Radiation Oncology, University of Tübingen, Tübingen, Germany; German Cancer Consortium (DKTK), partner site Tübingen, and German Cancer Research Center (DKFZ), Heidelberg, Germany; Cluster of Excellence "Machine Learning", University of Tübingen, Tübingen, Germany. Electronic address:

Purpose: To retrain a model based on a previously identified prognostic imaging biomarker using apparent diffusion coefficient (ADC) values from diffusion-weighted magnetic resonance imaging (DW-MRI) in a preclinical setting and validate the model using clinical DW-MRI data of patients with locally advanced head-and-neck cancer (HNC) acquired before radiochemotherapy.

Material And Methods: A total of 31 HNC patients underwent T2-weighted and DW-MRI using 3 T MRI before radiochemotherapy (35x2Gy). Gross tumor volumes (GTV) were delineated based on T2-weighted and b500 images.

View Article and Find Full Text PDF

causing Dieback disease in (Lour.) Per. in China.

Plant Dis

December 2024

Chinese Academy of Sciences, South China Botanical Garden, Guangzhou, Guangdong, China;

Litsea cubeba (Lour.) Per., named as May Cang, is a rare deciduous evergreen tree and cultivated for its ethnopharmacological properties and medicinal uses.

View Article and Find Full Text PDF

Purpose: To evaluate the utility of apparent diffusion coefficient (ADC) values of extraocular muscles (EOMs) in differentiating activity of thyroid eye disease (TED).

Method: Forty-two TED patients who underwent diffusion tensor imaging(DTI) were retrospectively enrolled in this study, including 29 patients in analysis group and 13 patients in validation group. The mean, maximum and minimum ADC value of each EOM were regarded as ADCmean, ADCmax and ADCmin.

View Article and Find Full Text PDF

Introduction: Arteriovenous fistula (AVF) maturation failure remains common despite preoperative ultrasound mapping. Identifying predictive biomarkers can help anticipate primary failure and reducing invasive procedures. Our study aimed to identify clinical and analytical risk factors for primary AVF failure or delay.

View Article and Find Full Text PDF

Enhanced Non-Invasive Diagnosis of Female Urinary Incontinence Using Static and Functional Transperineal Ultrasonography.

Diagnostics (Basel)

November 2024

Pulmonary Circulation Centre, Department of Cardiac and Vascular Diseases, Faculty of Medicine, Jagiellonian University Medical College, John Paul II Hospital in Kraków, 31-022 Kraków, Poland.

: To investigate the utility of transperineal ultrasound in detecting stress urinary incontinence (SUI) and identify optimal anatomical and functional parameters. : Thirty-four women presenting with SUI with or without pelvic organ prolapse between 2012 and 2016 were studied. The control group included patients without SUI who underwent surgery for mild gynecologic disorders or pelvic organ prolapse.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!