A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Long-Term Functional and Structural Durability of Bioprosthetic Valves Placed in the Aortic Valve Position via Percutaneous Rout in Israel. | LitMetric

There is limited organized "real life" data regarding the long-term structural and functional durability of transcatheter aortic valve implants, a topic of major importance. We assessed the 5-year structural and functional integrity outcomes following trans-catheter aortic valve implantation (TAVI) with both self-expandable and balloon-expandable prosthetic valve devices. This study included 450 consecutive patients who underwent TAVI for severe symptomatic aortic stenosis (AS) between September 2008 and December 2011. Data were acquired from a multicenter Israeli registry and the median follow up time was 5.6 years. In 184 patients (40.9%) who survived 5 years, prostheses displayed sustained hemodynamic performance, with average peak and mean aortic valve gradients of 16.2 ± 8.9 and 9.2 ± 6.6 mm Hg, respectively. Late structural valve deterioration was found in 22 (12.3%) patients. Of these, 16 (8.9%) experienced valve deterioration and 6 (3.3%) experienced valve failure. Among the 6 patients with bioprosthetic valve failure, only 3 underwent re-interventions. Bioprosthetic valve dysfunction occurred more frequently in patients with small valves (23 mm) and high peak and mean transvalvular gradients at baseline. In conclusion, a relatively low rate of valve deterioration or failure was noted in our long-term follow-up study after TAVI procedures with both the catheter-based self-expandable and balloon-expandable prosthetic valves.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2019.08.043DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
valve deterioration
12
valve
11
structural functional
8
self-expandable balloon-expandable
8
balloon-expandable prosthetic
8
experienced valve
8
valve failure
8
bioprosthetic valve
8
aortic
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!