Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In 2015, Zika virus (ZIKV) appeared as an emerging pathogen, generating a global and urgent need for accurate diagnostic devices. During this public health crisis, several nucleic acid testing (NAT)-based Zika assays were submitted to the US Food and Drug Administration (FDA) for Emergency Use Authorization. The FDA's Center for Devices and Radiological Health, in collaboration with the FDA's Center for Biologics Evaluation and Research, responded to this Zika emergency by developing and producing a reference panel (RP) for Zika RNA (Zika FDA-RP) suitable for performance assessment of ZIKV NAT-based in vitro diagnostic devices. Reference panels are a fundamental tool for performance assessment of molecular tests. The panel is composed of five vials: two different heat-inactivated ZIKV strains (PRVABC59 and FSS13025) in concentrated stocks and three blinded concentrations prepared from those strains. The Zika FDA-RP was shared with developers who had devices in the final stages of validation. In vitro diagnostic developers tested the Zika FDA-RP using the FDA-provided protocol. Depending on sample type, 85% (12/14) of the NAT assays had analytical sensitivities between 500 and 5000 RNA NAT-detectable units/mL (NDUs/mL). One device showed better performance (100 NDUs/mL), and another one showed lower performance (10,000 to 30,000 NDUs/mL). Vials of the Zika FDA-RP are available on request to developers who have interacted with the FDA through the review process.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jmoldx.2019.06.004 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!