Photoacoustic tomography (PAT) is intrinsically sensitive to blood oxygen saturation (sO2) in vivo. However, making accurate sO2 measurements without knowledge of tissue- and instrumentation-related correction factors is extremely challenging. We have developed a low-cost flow phantom to facilitate validation of PAT systems. The phantom is composed of a flow circuit of tubing partially embedded within a tissue-mimicking material, with independent sensors providing online monitoring of the optical absorption spectrum and partial pressure of oxygen in the tube. We first test the flow phantom using two small molecule dyes that are frequently used for photoacoustic imaging: methylene blue and indocyanine green. We then demonstrate the potential of the phantom for evaluating sO2 using chemical oxygenation and deoxygenation of blood in the circuit. Using this dynamic assessment of the photoacoustic sO2 measurement in phantoms in relation to a ground truth, we explore the influence of multispectral processing and spectral coloring on accurate assessment of sO2. Future studies could exploit this low-cost dynamic flow phantom to validate fluence correction algorithms and explore additional blood parameters such as pH and also absorptive and other properties of different fluids.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7005535 | PMC |
http://dx.doi.org/10.1117/1.JBO.24.12.121908 | DOI Listing |
Phys Med Biol
January 2025
Schlegel Research Institute for Aging, University of Waterloo, 250 Laurelwood Drive, Waterloo, Ontario, N2L 3G1, CANADA.
As ultrasound-compatible flow phantoms are devised for performance testing and calibration, there is a practical need to obtain independent flow measurements for validation using a gold-standard technique such as particle image velocimetry (PIV). In this paper, we present the design of a new dual-modality flow phantom that allows ultrasound and PIV measurements to be simultaneously performed. Our phantom's tissue mimicking material is based on a novel hydrogel formula that uses propylene glycol to lower the freezing temperature of an ultrasound-compatible poly(vinyl) alcohol cryogel and, in turn, maintain the solution's optical transparency after thermocycling.
View Article and Find Full Text PDFFront Optoelectron
January 2025
Institution of Physics, Saratov State University, Saratov, 410012, Russia.
Current study presents an advanced method for improving the visualization of subsurface blood vessels using laser speckle contrast imaging (LSCI), enhanced through principal component analysis (PCA) filtering. By combining LSCI and laser speckle entropy imaging with PCA filtering, the method effectively separates static and dynamic components of the speckle signal, significantly improving the accuracy of blood flow assessments, even in the presence of static scattering layers located above and below the vessel. Experiments conducted on optical phantoms, with the vessel depths ranging from 0.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Department of Chemistry, University of Victoria, PO Box 1700 Stn CSC, Victoria, BC V8W 2Y2, Canada.
Gold nanoparticles (GNPs) encapsulated in amphiphilic block copolymers are a promising system for numerous biomedical applications, although critical information on the effects of various preparation variables on the structure and properties of this unique type of nanomaterial is currently missing from the literature. In this research, we synthesized GNPs functionalized with thiol-terminated polycaprolactone (PCL-GNPs) before encapsulating them into poly(ε-caprolactone)--poly(ethylene glycol) (PCL--PEG) micellar nanoparticles via nanoprecipitation to yield GNP-loaded polymeric nanoparticles (GNP-PNPs). We explored the role of different manufacturing variables (water volume, PCL--PEG to PCL-GNP ratio, and PEG block length) on the sizes, morphologies, GNP occupancies, colloidal gold concentrations, and time stability of GNP-PNPs.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
February 2025
Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA.
Abdominal aortic aneurysm (AAA) is the focal dilation of the terminal aorta, which can lead to rupture if left untreated. Traditional endovascular aneurysm repair techniques are minimally invasive and pose low mortality rates compared with open surgical repair; however, endovascular aneurysm repair procedures face challenges in accommodating variations in the patient's anatomy. Complex aneurysms are defined when the sac extends past the renal arteries or has an insufficient neck landing zone to deploy a traditional endograft.
View Article and Find Full Text PDFMed Phys
December 2024
ICube Laboratory, University of Strasbourg UMR 7357 CNRS, Strasbourg, France.
Background: Percutaneous image-guided cementoplasty is a medical procedure for strengthening bones structurally altered by disease, such as osteolytic metastasis. This procedure involves injecting biocompatible liquid bone cement, through one or more trocars into the damaged bone. Within a few minutes the bone cement hardens and restores the rigidity of the bony structure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!