Objective: Dorsal stabilization is a frequently used procedure in the treatment of acute traumatic vertebral body fractures. Besides the traditional open surgical procedure, the percutaneous positioning of pedicle screws is now widely used. The aim of the current study is to compare pedicle screw misplacement following open vs. percutaneous dorsal instrumentation after traumatic spinal fracture of the thoracic and lumbar spine and to assess possible risk factors associated with pedicle screw misplacement.

Methods: All patients who suffered a traumatic spinal fracture that were treated with dorsal stabilization in our level I trauma center in the period from 01/2007 to 03/2014 were included in this retrospective therapeutic cohort study. From 01/2007 to 06/2009, an open surgical procedure was used, and from 06/2009 to 03/2014, the percutaneous procedure was used for all types of fractures. Retrospectively, the positioning of every single pedicle screw was evaluated in the post-operative computed tomography scan and classified. Epidemiological data were also documented to compare the two treatment groups.

Results: A total of 491 patients with 681 vertebral body fractures were included. Of 733 pedicle screws placed during the open surgery procedure, 96.0% were within the safe zone. There was no significant difference compared with pedicle screws placed percutaneously (95.3% of 1884 screws). In all other categories, the number of misplaced pedicle screws also showed no differences between the two treatment groups. There is a positive correlation between pedicle screw misplacement and duration of the operation. Most pedicle screws are misplaced at the levels T12, L1 and T7, T8.

Conclusion: The current study shows that percutaneous surgery using dorsal stabilization allows the positioning of pedicle screws in an equivalently safe manner compared with an open surgical procedure in the acute care of spinal trauma.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00068-019-01245-8DOI Listing

Publication Analysis

Top Keywords

pedicle screws
24
pedicle screw
20
screw misplacement
12
traumatic spinal
12
spinal fracture
12
dorsal stabilization
12
open surgical
12
surgical procedure
12
pedicle
10
misplacement open
8

Similar Publications

Background: Pedicle screw insertion in posterior spinal surgery can cause vascular injuries, including rare intercostal artery pseudoaneurysms, which are typically discovered incidentally during reimaging. Onyx embolization is an effective treatment for small artery pseudoaneurysms.

Observations: A 36-year-old man who had initially presented with back pain that remained unresponsive to nonsteroidal anti-inflammatory drugs was diagnosed with a T7-8 sarcomatous lesion confirmed by magnetic resonance imaging and biopsy.

View Article and Find Full Text PDF

Preserving Cervical Mobility: A Novel Robot-Assisted Approach for Atlas Fracture Fixation.

Am J Case Rep

January 2025

Department of Orthopedic Surgery, Sichuan Provincial People's Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.

BACKGROUND The management of unstable atlas fractures remains a subject of ongoing debate and controversy. The conservative surgical treatment commonly involves fusion, resulting in severe loss of cervical spine mobility, and a large incisions and extensive tissue dissection are required. We aim to introduce a novel concept and surgical approach for treating atlas fracture, one that involves minimizing trauma while maintaining mobility of the upper cervical spine without resorting to fusion.

View Article and Find Full Text PDF

Delayed diagnosis of spinal osteoblastoma presenting with radicular pain and scoliosis: A case report.

Int J Surg Case Rep

January 2025

University of Tunis El Manar, Faculty of Medicine of Tunis, 1007, Tunisia; Department of Orthopedic Surgery, Hospital Mongi Slim La Marsa, Tunisia.

Introduction And Importance: Osteoblastoma is a rare benign bone tumor, accounting for 1 % of primary bone tumors, often affecting the spine and sacrum. Accurate diagnosis is essential for appropriate treatment and prognosis.

Case Presentation: A 19-year-old male presented with two years of persistent nocturnal radicular and low back pain unresponsive to anti-inflammatory medications.

View Article and Find Full Text PDF

This descriptive longitudinal study aims to assess the risk factors for severe thoracic and lumbar vertebral compression fractures before and after surgery, contributing to preventive knowledge enhancement in communities and effective treatment management. The study involved 34 patients diagnosed with thoracic and lumbar vertebral compression fractures requiring surgery with bio-cement-augmented pedicle screws between June 2021 and June 2022. Postoperative complications, notably adjacent segment injury, were monitored, and patients received osteoporosis management post-surgery.

View Article and Find Full Text PDF

Cement-augmented pedicle screw instrumentation is a widely accepted method for managing osteoporotic fractures, but it carries inherent risks, particularly related to cement leakage and embolism. This study aimed to analyze a clinical case of complications following cement fixation and provide a detailed review of relevant literature. A 70-year-old patient underwent transpedicular screw instrumentation from L2-L4 with polymethyl methacrylate augmentation, which resulted in cement leakage into the spinal canal and subsequent pulmonary embolism.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!