Pulse-Wave-Pattern Classification with a Convolutional Neural Network.

Sci Rep

Graduate School of Biomedical Engineering, Tohoku University, 6-6 Aramaki-aza-aoba, Aoba-ku, Sendai, Miyagi, 980-8579, Japan.

Published: October 2019

Owing to the diversity of pulse-wave morphology, pulse-based diagnosis is difficult, especially pulse-wave-pattern classification (PWPC). A powerful method for PWPC is a convolutional neural network (CNN). It outperforms conventional methods in pattern classification due to extracting informative abstraction and features. For previous PWPC criteria, the relationship between pulse and disease types is not clear. In order to improve the clinical practicability, there is a need for a CNN model to find the one-to-one correspondence between pulse pattern and disease categories. In this study, five cardiovascular diseases (CVD) and complications were extracted from medical records as classification criteria to build pulse data set 1. Four physiological parameters closely related to the selected diseases were also extracted as classification criteria to build data set 2. An optimized CNN model with stronger feature extraction capability for pulse signals was proposed, which achieved PWPC with 95% accuracy in data set 1 and 89% accuracy in data set 2. It demonstrated that pulse waves are the result of multiple physiological parameters. There are limitations when using a single physiological parameter to characterise the overall pulse pattern. The proposed CNN model can achieve high accuracy of PWPC while using CVD and complication categories as classification criteria.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6797811PMC
http://dx.doi.org/10.1038/s41598-019-51334-2DOI Listing

Publication Analysis

Top Keywords

data set
16
cnn model
12
classification criteria
12
pulse-wave-pattern classification
8
convolutional neural
8
neural network
8
pulse pattern
8
criteria build
8
physiological parameters
8
accuracy data
8

Similar Publications

Novel Data Fusion Strategy for Second-Order Data: Multivariate Curve Resolution for the Determination of Pharmaceuticals by Means of Fluorimetric Measurements.

Anal Chem

January 2025

Laboratorio de Investigación y Desarrollo en Métodos Analíticos (LIDMA), Facultad de Ciencias Exactas, Universidad Nacional de La Plata (UNLP), Calle 49 y 115 (B1900AJL), La Plata 1900, Argentina.

A new strategy is proposed for second-order data fusion based on the simultaneous modeling of two data sets using the multivariate curve resolution-alternating least-squares (MCR-ALS) model, applying a new constraint during the ALS stage, called "Proportionality of Scores". This approach allows for the fusion of data from different sources, without requiring common dimensionality, and enables the application of specific constraints to each data set. This strategy was applied to the determination of five pharmaceutical contaminants (naproxen, danofloxacin, ofloxacin, sarafloxacin, and enoxacin) in environmental water samples, by fusing two sets of excitation-emission fluorescence matrices, measured before and after photochemical derivatization.

View Article and Find Full Text PDF

Quality control procedures play a pivotal role in ensuring the reliability and consistency of data generated in mass spectrometry-based proteomics laboratories. However, the lack of standardized quality control practices across laboratories poses challenges for data comparability and reproducibility. In response, we conducted a harmonization study within proteomics laboratories of the Core for Life alliance with the aim of establishing a common quality control framework, which facilitates comprehensive quality assessment and identification of potential sources of performance drift.

View Article and Find Full Text PDF

Magnesium plays an important role in the hardening mechanism of aluminum alloys, but sensitisation-induced intergranular corrosion cracking limits the widespread use of aluminum alloy in equipment. For on-site quantitative assessment of sensitisation in 5-series aluminum alloys, a laser-induced plasma imaging technique is proposed, which evaluates the degree of aluminum alloy sensitisation by obtaining images of the plasma formed by laser ablation of aluminum alloys, and then classifying and quantifying the images using a residual network. Compared to EMAT, XRD, ECT and LIBS techniques, the sample surface only needs to be polished, does not consume chemical reagents and is not affected by the shape and thickness of the workpiece, which provides higher quantitative accuracy, stability and detection efficiency.

View Article and Find Full Text PDF

Dissolved organic matter (DOM) present in surface aquatic systems is a heterogeneous mixture of organic compounds reflecting its allochthonous and autochthonous organic matter (OM) sources. The composition of DOM is determined by environmental factors like land use, water chemistry, and climate, which influence its release, movement, and turnover in the ecosystem. However, studying the impact of these environmental factors on DOM composition is challenging due to the dynamic nature of the system and the complex interactions of multiple environmental factors involved.

View Article and Find Full Text PDF

Analysis strategy of contamination source using chemical fingerprint information based on GC-HRMS: A case study of landfill leachate.

Water Res

December 2024

College of Environment, Ministry of Education Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes, Hohai University, Nanjing 210098, PR China.; Suzhou Research Institute, Hohai University, Suzhou 215100, PR China.. Electronic address:

With the increasing prevalence of emerging contaminants (ECs) in the environment, gaining a deeper understanding of the chemical information pertaining to the contamination source is a crucial step toward effective prevention and control of these ECs. This study presents a novel strategy for analyzing the chemical information of contamination sources using gas chromatography-high resolution mass spectrometry (GC-HRMS) and demonstrates it on landfill leachate, a common and representative environmental contamination source. Initially, a non-targeted screening approach using HRMS was used to characterize a total of 5344 organic compounds with identification confidence levels 1 and 2 in 14 landfill leachate samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?