A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An improvement of electrospun membrane reusability via titanium dioxide nanoparticles and silane compounds for the electromembrane extraction. | LitMetric

A polyacrylonitrile (PAN)/polydimethylsiloxane (PDMS) flat membrane was fabricated by electrospinning technique and modified using titanium dioxide (TiO) nanoparticles and low-energy materials, dimethyldichlorosilane (MeSiCl)/methyltrichlorosilane (MeSiCl), to obtain a hydrophobic surface. The new membrane was utilized for the electromembrane extraction (EME) of model molecules including dibutyl phthalate (DBP) and bis [2-ethylhexyl] phthalate (DEHP). The parameters affecting proposed EME were optimized by the response surface methodology (RSM) based on the central composite design (CCD). The optimized values were 200 V of voltage, 20 min of extraction time, 1100 rpm of agitation rate, 10 mL of donor phase volume and 1 mL of acceptor phase volume. From the results, the performance of EME with the new (modified) membrane remained almost constant after ten extraction cycles while the extraction performance of unmodified EME steeply fell after six extraction cycles. The limits of detection (LODs) for DBP and DEHP were 7.40 and 0.08 ng mL, respectively. The linear dynamic range (LDR) was in the range of 100-4000 ng mL for DBP and 1-2000 ng mL for DEHP. The relative standard deviations (RSDs) were below 10%, and the relative recoveries were over 86%. The overall energy consumption for the extraction of the model molecules by new EME was 13.4 kWh m. The approach is time-efficient and cost-effective, as the fabricated membrane has better reusability than the previous membranes used for EME.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.aca.2019.08.050DOI Listing

Publication Analysis

Top Keywords

titanium dioxide
8
electromembrane extraction
8
model molecules
8
phase volume
8
extraction cycles
8
extraction
7
eme
6
membrane
5
improvement electrospun
4
electrospun membrane
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!