Reverse rim sign on CEUS.

Abdom Radiol (NY)

Mayo Clinic Jacksonville, 4500 San Pablo Road, Jacksonville, FL, 32224, USA.

Published: January 2020

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00261-019-02273-zDOI Listing

Publication Analysis

Top Keywords

reverse rim
4
rim sign
4
sign ceus
4
reverse
1
sign
1
ceus
1

Similar Publications

Background: While outcomes following reverse shoulder arthroplasty (rTSA) have often been gauged through radiological assessments focusing on prosthesis position, there is increasing recognition of patient-reported outcomes, particularly satisfaction, as indicators of surgical success. The objective of this study was to correlate radiological findings with clinical outcomes, patient satisfaction, and health-related quality of life (HRQoL).

Materials And Methods: A retrospective evaluation was conducted on patients following rTSA at a minimum of two years postoperatively.

View Article and Find Full Text PDF

Zwitterion Interlocked Diarylethene Molecules Order, Unconnected Diarylethene Molecules Disorder.

Small

December 2024

Department of Polymer-Nano Science and Technology, Department of Nano Convergence Engineering, Jeonbuk National University, Jeonju, 54896, Republic of Korea.

A diarylethene-based zwitterionic molecule (DZM) is newly synthesized for the development of smart films exhibiting reversible color change and switchable ionic conductivity in response to external light stimuli. This dual molecular building block is constructed through zwitterionic interlocking and strong phase separation between the dendron-shaped aliphatic tails and the diarylethene head. Uniaxial shear coating and molecular self-assembly result in anisotropically oriented nanostructures, which are further solidified through photopolymerization.

View Article and Find Full Text PDF

Background: In reverse total shoulder arthroplasty, a humeral osteotomy is typically performed at the anatomic neck. The quality and quantity of cancellous and cortical bone impacts sizing of implants. Little-to-no information exists characterizing the transition of this bone quality at this location.

View Article and Find Full Text PDF

Reverse Shoulder Arthroplasty Implant Design and Configuration has a Significant Effect on Conjoint Tendon Impingement.

J Shoulder Elbow Surg

December 2024

Roth | McFarlane Hand and Upper Limb Centre, St Joseph's Health Care, London, Canada; Department of Surgery, Western University, London, Canada. Electronic address:

Background: Anterior shoulder pain after reverse shoulder arthroplasty (RSA) is not uncommon and may be due to humeral impingement against the conjoint tendon during internal rotation (IR). It is unknown what effect different implant designs and configurations have on conjoint tendon impingement. The purpose of this study was to investigate the influence of several RSA implant design parameters on conjoint tendon impingement during IR.

View Article and Find Full Text PDF

Aiming at the problem of excessive swelling of conventional microspheres for oilfield use, a novel amphiphilic polymerizable crosslinker (AE) was synthesized by quaternary ammonium modification of an unstable crosslinker (AE) using acrylamide, 2-acrylamido-2-methylpropanesulfonic acid as the monomers, N,N'-methylene bisacrylamide as the stabilizing crosslinker, ammonium peroxysulfate and sodium bisulfite as the initiator, and water as the solvent by using a reversed microemulsion method. Double-networked nanomicrospheres were prepared. The preparation conditions of the microspheres were optimized by the surface response method, focusing on the effects of the initiator addition and reaction temperature, and total crosslinker addition on the formation of nanomicrospheres.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!