Background: Intra-operative image acquisition can be obtained indirectly (via verbal request to a technician) or directly (executed at the tableside, by a surgeon stepping on a foot pedal). Direct image acquisition could reduce the exposure time and thus the risk of radiation damage. The aim of this randomized controlled trial was to compare direct surgeon-controlled fluoroscopy with indirect technician-operated fluoroscopy during internal fixation of a hip fracture.

Methods: From March 5, 2014 to August 19, 2015, 100 patients who had sustained a hip fracture that required internal fixation were enrolled. Patients were randomized between direct surgeon-controlled image acquisition using a foot pedal (n = 52) and indirect image acquisition by a radiology technician (n = 48). The primary outcome measure was the radiation exposure time; secondary outcome measures were the associated effective radiation dose and the dose area product.

(dap) Results: A total of 96 patients (with a median age of 84 years) were enrolled in this study. Eighty-nine (93%) patients had a pertrochanteric fracture. No statistically significant differences between direct image acquisition and indirect image acquisition were found for overall radiation time, total radiation dose or DAP for the total population. When adjusted for potential confounders, a difference in overall radiation time of 18.50 s (95% CI 2.19; 34.81, p = 0.027) was found in favour of indirect image acquisition.

Conclusion: This study showed statistically significantly lower radiation duration using indirect fluoroscopy for the total population and the pertrochanteric fracture subgroup when adjusted for several confounders. No significant effect on radiation dose and DAP was found.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2019.09.035DOI Listing

Publication Analysis

Top Keywords

image acquisition
28
indirect image
16
internal fixation
12
radiation dose
12
radiation
9
radiation exposure
8
image
8
fixation hip
8
hip fracture
8
randomized controlled
8

Similar Publications

Background: Tibiofemoral rotation is an emerging parameter, especially in assessing patellofemoral instability. However, reference values in the literature are inconsistent regarding the used imaging modality and do not consider the effect of knee flexion during image acquisition.

Purpose: To analyze the differences in tibiofemoral rotation measurements between computed tomography (CT) and magnetic resonance imaging (MRI).

View Article and Find Full Text PDF

Rhinoplasty is one of the major surgical procedures most popular and it is generally performed modelling the internal bones and cartilage using a closed approach to reduce the damage of soft tissue, whose final shape is determined by means of their new settlement over the internal remodelled rigid structures. An optimal planning, achievable thanks to advanced acquisition of 3D images and thanks to the virtual simulation of the intervention via specific software. Anyway, the final result depends also on factors that cannot be totally predicted regarding the settlement of soft tissues on the rigid structures, and a final objective check would be useful to eventually perform some adjustments before to conclude the intervention.

View Article and Find Full Text PDF

The human body is an intricate system, where diverse and complex signaling among different organs sustains physiological activities. The eye, as a primary organ for information acquisition, not only plays a crucial role in visual perception but also, as increasing evidence suggests, exerts a broad influence on the entire body through complex circuits upon receiving light signals which is called non-image-forming vision. However, the extent and mechanisms of light's impact on the body through the eyes remain insufficiently explored.

View Article and Find Full Text PDF

Establishing a standardized murine orthotopic intra-rectal model for the study of colorectal adenocarcinoma.

J Gastrointest Oncol

December 2024

Medical Physics Unit, Department of Oncology, Faculty of Medicine, McGill University, Montreal, QC, Canada.

Background: Orthotopic models offer a more accurate representation of colorectal cancer (CRC) compared to subcutaneous models. Despite promising results from the reported intra-rectal models, establishing a standardized method for CRC research remains challenging due to model variability, hindering comprehensive studies on CRC pathogenesis and treatment modalities, such as brachytherapy. This study aimed to establish a standardized workflow for an orthotopic intra-rectal animal model to induce the growth of colorectal adenocarcinoma in male and female mice.

View Article and Find Full Text PDF

Purpose: To provide a fast quantitative imaging approach for a 0.55T scanner, where signal-to-noise ratio is limited by the field strength and k-space sampling speed is limited by a lower specification gradient system.

Methods: We adapted the three-dimensional spiral projection imaging MR fingerprinting approach to 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!