In presence of inter-fractional anatomical changes, clinical benefits are anticipated from image-guided adaptive radiotherapy. Nowadays, cone-beam CT (CBCT) imaging is mostly utilized during pre-treatment imaging for position verification. Due to various artifacts, image quality is typically not sufficient for photon or proton dose calculation, thus demanding accurate CBCT correction, as potentially provided by deep learning techniques. This work aimed at investigating the feasibility of utilizing a cycle-consistent generative adversarial network (cycleGAN) for prostate CBCT correction using unpaired training. Thirty-three patients were included. The network was trained to translate uncorrected, original CBCT images (CBCT) into planning CT equivalent images (CBCT). HU accuracy was determined by comparison to a previously validated CBCT correction technique (CBCT). Dosimetric accuracy was inferred for volumetric-modulated arc photon therapy (VMAT) and opposing single-field uniform dose (OSFUD) proton plans, optimized on CBCT and recalculated on CBCT. Single-sided SFUD proton plans were utilized to assess proton range accuracy. The mean HU error of CBCT with respect to CBCT decreased from 24 HU for CBCT to -6 HU. Dose calculation accuracy was high for VMAT, with average pass-rates of 100%/89% for a 2%/1% dose difference criterion. For proton OSFUD plans, the average pass-rate for a 2% dose difference criterion was 80%. Using a (2%, 2 mm) gamma criterion, the pass-rate was 96%. 93% of all analyzed SFUD profiles had a range agreement better than 3 mm. CBCT correction time was reduced from 6-10 min for CBCT to 10 s for CBCT. Our study demonstrated the feasibility of utilizing a cycleGAN for CBCT correction, achieving high dose calculation accuracy for VMAT. For proton therapy, further improvements may be required. Due to unpaired training, the approach does not rely on anatomically consistent training data or potentially inaccurate deformable image registration. The substantial speed-up for CBCT correction renders the method particularly interesting for adaptive radiotherapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/ab4d8c | DOI Listing |
Cureus
December 2024
Department of Orthodontics, Kothiwal Dental College and Research Centre, Moradabad, IND.
Introduction The role of the condylar position in the correct functioning of the stomatognathic system has been the center of the study. Using cone-beam computed tomography (CBCT), this study looked at the three-dimensional (3D) position of the condylar bone in patients from Class I, Class II, Division 1, and Division 2. Materials and methods This cross-sectional, retrospective study was conducted using 102 CBCT records, with 34 records allocated to each category of malocclusion classification, such as dentoskeletal Class I, skeletal Class II, and dental Class II, Division 1 and 2.
View Article and Find Full Text PDFPhys Imaging Radiat Oncol
January 2025
Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam, The Netherlands.
Background And Purpose: A novel ring-gantry cone-beam computed tomography (CBCT) imaging system shows improved image quality compared to its conventional version, but its effect on autosegmentation is unknown. This study evaluates the impact of this high-performance CBCT on autosegmentation performance, inter-observer variability, contour correction times and delineation confidence, compared to the conventional CBCT.
Materials And Methods: Twenty prostate cancer patients were enrolled in this prospective clinical study.
J Med Imaging Radiat Oncol
January 2025
Department of Radiation Oncology, Townsville University Hospital, Townsville, Queensland, Australia.
Introduction: Prostate motion during external beam radiotherapy (EBRT) is common and typically managed using fiducial markers and cone beam CT (CBCT) scans for inter-fractional motion correction. However, real-time intra-fractional motion management is less commonly implemented. This study evaluated the extent of intra-fractional prostate motion using transperineal ultrasound (TPUS) and examined the impact of treatment time on prostate motion.
View Article and Find Full Text PDFAppl Radiat Isot
January 2025
Department of Medical Physics, Medical School, University of Crete, Heraklion, Greece. Electronic address:
Purpose: Surface Guided Radiation Treatment (SGRT) is a new method of positioning and monitoring patients on the linear accelerator's couch, using visual light cameras to monitor the skin's surface. The purpose of this study was to compare the SGRT with the conventional method, based on lasers and tattoos, in terms of accuracy and time expenditure, on patients with pelvic malignancies.
Materials And Methods: A group of 34 patients were enrolled in this study, 24 males who underwent radiotherapy prostate treatment and 10 females who underwent gynecological radiation therapy.
BMC Oral Health
January 2025
Resident of Oral and Maxillofacial Radiology, Isfahan University of Medical Sciences, Isfahan, Iran.
Background: Early detection of peri-implant bone defects can improve long-term durability of dental implants. By the advances in cone-beam computed tomography (CBCT) scanners and introduction of new algorithms, it is important to find the most efficient protocol for detection of bone defects. This study aimed to assess the efficacy of metal artifact reduction (MAR) and advanced noise reduction (ANR) algorithms for detection of peri-implant bone defects.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!