Assessment of health effects from low-dose radiation exposures in patients undergoing diagnostic imaging is an active area of research. High-quality dosimetry information pertaining to these medical exposures is generally not readily available to clinicians or epidemiologists studying radiation-related health risks. The purpose of this study was to provide methods for organ dose estimation in pediatric patients undergoing four common diagnostic fluoroscopy procedures: the upper gastrointestinal (UGI) series, the lower gastrointestinal (LGI) series, the voiding cystourethrogram (VCUG) and the modified barium swallow (MBS). Abstracted X-ray film data and physician interviews were combined to generate procedure outlines detailing X-ray beam projections, imaged anatomy, length of X-ray exposure, and presence and amount of contrast within imaged anatomy. Monte Carlo radiation transport simulations were completed for each of the four diagnostic fluoroscopy procedures across the 162-member (87 males and 75 females) University of Florida/National Cancer Institute pediatric phantom library, which covers variations in both subject height and weight. Absorbed doses to 28 organs, including the active marrow and bone endosteum, were assigned for all 162 phantoms by procedure. Additionally, we provide dose coefficients (DCs) in a series of supplementary tables. The DCs give organ doses normalized to procedure-specific dose metrics, including: air kerma-area product (µGy/mGy · cm), air kerma at the reference point (µGy/µGy), number of spot films (SF) (µGy/number of SFs) and total fluoroscopy time (µGy/s). Organs accumulating the highest absorbed doses per procedure were as follows: kidneys between 0.9-25.4 mGy, 1.1-16.6 mGy and 1.1-9.7 mGy for the UGI, LGI and VCUG procedures, respectively, and salivary glands between 0.2-3.7 mGy for the MBS procedure. Average values of detriment-weighted dose, a phantom-specific surrogate for the effective dose based on ICRP Publication 103 tissue-weighting factors, were 0.98 mSv, 1.16 mSv, 0.83 mSv and 0.15 mSv for the UGI, LGI, VCUG and MBS procedures, respectively. Scalable database of organ dose coefficients by patient sex, height and weight, and by procedure exposure time, reference point air kerma, kerma-area product or number of spot films, allows clinicians and researchers to compute organ absorbed doses based on their institution-specific and patient-specific dose metrics. In addition to informing on patient dosimetry, this work has the potential to facilitate exposure assessments in epidemiological studies designed to investigate radiation-related risks.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1667/RR15445.1 | DOI Listing |
Sci Rep
December 2024
Department of Cardiology, West China Hospital of Sichuan University, 37 Guoxue Alley, Wuhou District, Chengdu, 610041, Sichuan, China.
Intracardiac echocardiography (ICE) has been used to guide radio-frequency catheter ablation (RFCA) for better catheter navigation and less radiation exposure in treating atrial fibrillation (AF). This retrospective cohort study enrolled 227 AF patients undergoing ICE- or traditional fluoroscopy (TF)-guided RFCA for AF in a tertiary hospital. ICE was used more often in patients with atrial tachycardia [odds ratio (OR) 3.
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2024
Department of Orthopaedics and Traumatology, The First Affiliated Hospital of Zhejiang Chinese Medical University, 54 Youdian Road, Shangcheng District, Hangzhou, 310006, China.
Background: This study evaluated the clinical effects of the use of a temporary bi-frame fixator in conjunction with minimally invasive percutaneous plate osteosynthesis (MIPPO) for treating AO/OTA 41B3 and 41C tibial plateau fractures (TPFs).
Methods: This was a retrospective analysis of 30 patients with TPFs affected by vertical compression seen from October 2019 to October 2020. All patients were treated with a bi-frame fixator to correct the vertical shortening deformity, with the MIPPO technique used after reduction.
Eur J Radiol
December 2024
The Health Information and Quality Authority (HIQA), Unit 1301, City Gate, Mahon, Cork, T12 Y2xt Cork, Ireland. Electronic address:
Purpose: The purpose of this work was to establish national Irish diagnostic reference levels (DRLs) for a clinically representative and comprehensive list of clinical indications, anatomical regions, and common procedures for fluoroscopy and fluoroscopically guided interventions and compare these, where possible, to other DRLs established at a national level.
Method: A list of clinical indications, anatomical regions and common procedures was established. A national database of service providers was used to identify all medical radiological facilities providing fluoroscopy and fluoroscopically guided intervention services.
Catheter Cardiovasc Interv
December 2024
Radiology Unit, University Hospital Dulbecco, Catanzaro, Italy.
Background: Venous outflow is the favored access for endovascular management of dialysis fistulas. However, transradial access (TRA) offers advantages in specific clinical scenarios. The study aims to compare the efficacy, feasibility, and safety of TRA and transvenous access (TVA) in the endovascular management of malfunctioning dialysis fistulas, addressing the existing gap in comprehensive literature.
View Article and Find Full Text PDFOchsner J
January 2024
Department of Anesthesiology, Super Specialty, MGM Medical College, Indore, India.
Knee osteoarthritis is a chronic degenerative disease associated with pain and decreased mobility that affects advanced-age individuals, thus causing further debilitation. Radiofrequency ablation can benefit patients who are not ideal candidates for surgical intervention and for whom conservative management has been unsatisfactory. Currently, radiofrequency ablation is performed using either ultrasonography or fluoroscopy.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!