Simple measurement tools that provide objective information about the consistency of thickened liquids have received increasing attention given possible application to clinical practice for dysphagia. The International Dysphagia Diet Standardization Initiative (IDDSI) advocates the use of the IDDSI Flow Test for measuring thickness and verifying a prescribed level of consistency. This study compares gravity flow test measurements taken with two 10-ml syringes of starch and gum-thickened samples prepared to a mildly thick consistency using product label information. One of the 10-ml syringes met IDDSI specification and the other 10-ml syringe did not. Thickened samples also were measured using the line spread apparatus. The results showed that two syringes yielded significantly different gravity flow test measurements, often resulting in changes to the classification level of thickness. There was no effect of thickening agent. Line spread measurements did not vary from one another. Study findings indicate the importance of continued testing with the IDDSI Flow Test and education/awareness about the use of the IDDSI reference syringe. An essential aspect about the use of thickened liquids in dysphagia management is that beverage preparations represent their prescribed level of modification. The findings of this study indicate the importance of following syringe specifications when conducting gravity flow testing using the IDDSI methodology. The implication is that the wrong 10-ml syringe could result in errant clinical decisions in determining the accuracy of texture modifications, resulting in care providers who are more likely to over or under thicken modifications to achieve a targeted level of thickness.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jtxs.12491 | DOI Listing |
Biomed Microdevices
January 2025
Chakri Naruebodindra Medical Institute, Faculty of Medicine Ramathibodi Hospital, Mahidol University, 111 Suwannabhumi Canal Rd, Bang Pla, Bang Phli District, Samut Prakan, 10540, Thailand.
Microfluidic chips often face challenges related to the formation and accumulation of air bubbles, which can hinder their performance. This study investigated a bubble trapping mechanism integrated into microfluidic chip to address this issue. Microfluidic chip design includes a high shear stress section of fluid flow that can generate up to 2.
View Article and Find Full Text PDFExp Hematol Oncol
January 2025
Cancer Science Institute of Singapore, National University of Singapore, Singapore, Singapore.
Background: Radiotherapy is the primary treatment modality for most head and neck cancers (HNCs). Despite the addition of chemotherapy to radiotherapy to enhance its tumoricidal effects, almost a third of HNC patients suffer from locoregional relapses. Salvage therapy options for such recurrences are limited and often suboptimal, partly owing to divergent tumor and microenvironmental factors underpinning radioresistance.
View Article and Find Full Text PDFJ Biomed Sci
January 2025
Guangdong Provincial Key Laboratory of New Drug Design and Evaluation, State Key Laboratory of Anti-Infective Drug Discovery and Development, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, 510006, China.
Background: Recent studies indicate that N6-methyladenosine (mA) RNA modification may regulate ferroptosis in cancer cells, while its molecular mechanisms require further investigation.
Methods: Liquid Chromatography-Tandem Mass Spectrometry (HPLC/MS/MS) was used to detect changes in mA levels in cells. Transmission electron microscopy and flow cytometry were used to detect mitochondrial reactive oxygen species (ROS).
Anal Chim Acta
February 2025
Department of Biochemistry and Molecular Biology, Chang Gung University, Taoyuan, 333, Taiwan; Clinical Proteomics Core Laboratory, LinKou Chang Gung Memorial Hospital, Taoyuan, 333423, Taiwan. Electronic address:
Background: Tissue metabolomics analysis, alongside genomics and proteomics, offers crucial insights into the regulatory mechanisms of tumorigenesis. To enhance metabolite detection sensitivity, chemical isotope labeling (CIL) techniques, such as dansylation, have been developed to improve metabolite separation and ionization in mass spectrometry (MS). However, the dissolution of hydrophobic derivatized metabolites in solvents with high acetonitrile content limits the use of liquid chromatography (LC) systems with small-volume reversed-phase (RP) columns.
View Article and Find Full Text PDFSci Total Environ
January 2025
Ability R&D Energy Research Centre, School of Energy and Environment, City University of Hong Kong, Hong Kong; State Key Laboratory of Marine Pollution, City University of Hong Kong, Hong Kong.
The in-situ electrochemical production of hydrogen peroxide (HO) offers a promising approach for ballast water treatment. However, further advancements are required to develop electrocatalysts capable of achieving efficient HO generation in seawater environments. Herein, we synthesized two-dimensional lamellated porous carbon nanosheets enriched with oxygen functional groups, which exhibited exceptional performance in HO electrosynthesis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!