Ultrahigh-Performance capillary liquid chromatography-mass spectrometry at 35 kpsi for separation of lipids.

J Chromatogr A

Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA; Department of Pharmacology, University of Michigan, Ann Arbor, MI 48109, USA. Electronic address:

Published: January 2020

Improvements in sample preparation, separation, and mass spectrometry continue to expand the coverage in LC-MS based lipidomics. While longer columns packed with smaller particles in theory give higher separation performance compared to shorter columns, the implementation of this technology above commercial limits has been sparse due to difficulties in packing long columns and successfully operating instruments at ultrahigh pressures. In this work, a liquid chromatograph that operates up to 35 kpsi was investigated for the separation and identification of lipid species from human plasma. Capillary columns between 15-50 cm long were packed with 1.7 µm BEH C18 particles and evaluated for their ability to separate lipid isomers and complex lipid extracts from human plasma. Putative lipid class identifications were assigned using accurate mass and relative retention time data of the eluting peaks. Our findings indicate that longer columns packed and operated at 35 kpsi outperform shorter columns packed and run at lower pressures in terms of peak capacity and numbers of features identified. Packing columns with relatively high concentration slurries (200 mg/mL) while sonicating the column resulted in 6-34% increase in peak capacity for 50 cm columns compared to lower slurry concentrations and no sonication. For a given analysis time, 50 cm long columns operated at 35 kpsi provided a 20-95% increase in chromatographic peak capacity compared with 15 cm columns operated at 15 kpsi. Analysis times up to 4 h were evaluated, generating peak capacities up to 410 ± 5 (n = 3, measured at 4σ) and identifying 480 ± 85 lipids (n = 2). Importantly, the results also show a correlation between the peak capacity and the number of lipids identified from a human plasma extract. This correlation indicates that ionization suppression is a limiting factor in obtaining sufficient signal for identification by mass spectrometry. The result also shows that the higher resolution obtained by shallow gradients overcomes possible signal reduction due to broader, more dilute peaks in long gradients for improving detection of lipids in LC-MS. Lastly, longer columns operated at shallow gradients allowed for the best separation of both regional and geometrical isomers. These results demonstrate a system that enables the advantages of using longer columns packed and run at ultrahigh pressure for improving lipid separations and lipidome coverage.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6980658PMC
http://dx.doi.org/10.1016/j.chroma.2019.460575DOI Listing

Publication Analysis

Top Keywords

longer columns
16
columns packed
16
peak capacity
16
columns
12
human plasma
12
columns operated
12
mass spectrometry
8
shorter columns
8
long columns
8
operated 35 kpsi
8

Similar Publications

In China, a significant amount of coal fly ash is stored or used for landfill reclamation. The contaminants in coal fly ash (CFA) leachate can cause regional soil and groundwater contamination during long-term storage. This paper focuses on a coal gangue comprehensive utilisation power plant in Fenyang City, Shanxi Province, China, where the leaching characteristics of CFA were investigated by leaching tests.

View Article and Find Full Text PDF

Combination of atom transfer radical polymerization and alkyne-azide click-chemistry for the synthesis of phosphonic acid cation exchange materials.

J Chromatogr A

January 2025

Faculty of Chemistry, Analytical Chemistry, University of Marburg, Hans-Meerwein-Str. 4, Marburg 35043, Germany. Electronic address:

Phosphonic acid cation exchange materials (PCX) are synthesized by atom transfer radical polymerization (ATRP) followed by alkyne-azide click-chemistry. ATRP is used to synthesize polymeric chains of diethyl 4-vinylbenzylphosphonate with different chain lengths, which are covalently bonded to the surface of monodisperse polystyrene-divinylbenzene (PS/DVB) particles by click-chemistry. The functionalized particles are characterized by FIB-SEM, IR and Schoeniger combustion followed by chromatographic experiments.

View Article and Find Full Text PDF

Ossification of the posterior longitudinal ligament of the vertebral column (OPLL) is a disease characterised by ectopic bone formation in the spinal ligament that causes progressive neurological impairment. However, there are no suitable treatments for OPLL. Here, we compared the general characteristics and haemostasis of patients with OPLL and those with cervical spondylotic myelopathy.

View Article and Find Full Text PDF

A hydrodynamic antenna: novel lateral line system in the tail of myliobatid stingrays.

Proc Biol Sci

January 2025

Department of Organismic and Evolutionary Biology, Harvard University, 26 Oxford Street, Cambridge, MA 02138, USA.

Eagle rays, cownose rays and manta rays (order Myliobatiformes) have a slender tail that can be longer than the animal's body length, but its function and structure are unknown. Using histology, immunohistochemistry and three-dimensional imaging with micro-computed tomography scans, we describe the anatomy and function of the tail in , the cownose ray. The tail is an extension of the vertebral column with unique morphological specializations.

View Article and Find Full Text PDF

Background: Fast-acting Sub-perception Therapy (FAST) is a novel spinal cord stimulation (SCS) modality delivering paresthesia-free pain relief. Our study evaluated the longer-term, real-world impact of FAST on chronic pain.

Research Design And Methods: As part of a multicenter, real-world, consecutive case series, we retrospectively identified patients who used FAST-SCS and analyzed their data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!