In order to evaluate the quality of Styrax more comprehensively,this study attempted to establish an HPLC wavelength switching method to simultaneously determine the content of seven compounds in Styrax,and chemometrics were used to analyze the quality difference between different sources of Styrax,and finally establish a characteristic chromatogram of Styrax. The column was Agilent ZORBAX Extend C18( 4. 6 mm×250 mm,5 μm) with phase a mixture of acetonitrile-0. 1% phosphoric acid aqueous solution as the mobile phase in a gradient elution procedure; the detection wavelength was set as follows: 0-13. 5 min,194 nm( benzoic acid);13. 5-20. 5 min,278 nm( cinnamic acid); 20. 5-32 min,194 nm( benzyl benzoate,benzyl cinnamate,cinnamyl cinnamate,dehydroabietic acid); 32-55 min,241 nm( abietic acid). The methodological verification results showed that when the injection masses of benzoic acid,cinnamic acid,benzyl benzoate,benzyl cinnamate,cinnamyl cinnamate,dehydroabietic acid and abietic acid were0. 006 948-0. 694 8,0. 001 426-0. 142 6,0. 013 16-0. 658 0,0. 006 148-0. 614 8,0. 008 035-0. 803 5,0. 002 121-0. 212 1,and0. 010 172-1. 017 2 μg,respectively,there were good linear relationship between injection mass and peak area. The average recovery rates of seven compounds were in the range from 94. 34% to 105. 8%,and all RSD were less than 3. 0%( n = 6). The methodological verification results showed that the developed HPLC wavelength switching method has good accuracy and repeatability. The results of the sample analysis showed that the quality of Styrax from different sources was quite different. The chromatogram of Styrax reference material( S1) was used as the reference chromatogram to calculate the fingerprint similarity of each batch of samples. The results showed that the similarities of samples S2-S10 were 0. 952,0. 949,0. 981,0. 351,0. 751,0. 969,0. 979,0. 992 and 0. 971,respectively.The similarity values of other batches samples were satisfactory,except for sample S5 and S6,indicating that the quality difference among these samples is small. The similarity values of S11-S20 were 0. 060,0. 055,0. 054,0. 285,0. 092,0. 002,0. 044,0. 044,0. 044,and 0. 040,respectively. The results showed that compared with the sample S1,there was a large quality difference among S11-S20. Based on the chromatograms of S1-S10,the HPLC characteristic chromatograms of Styrax was established and the purpose is to give reference to other pharmaceutical researchers. The newly developed HPLC wavelength switching method have the advantages of simplicity,reproducibility and specificity,and the developed HPLC characteristic chromatograms provided a reference method for the overall quality evaluation of Styrax.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.19540/j.cnki.cjcmm.20190423.201 | DOI Listing |
J Chromatogr B Analyt Technol Biomed Life Sci
January 2025
Université Clermont Auvergne, Institut Universitaire de Technologie, UMR INSERM-UCA, U1240, Imagerie Moléculaire et Stratégies Théranostiques (IMoST), 5 Avenue Blaise Pascal, 63000 Clermont-Ferrand, France.
A method using high-performance liquid chromatography coupled with fluorescence detection (HPLC-FLD) was developed and validated to quantify the innovative tool LightSpot®-FL-1, a selective permeability-glycoprotein (P-gp)-targeted fluorescent conjugate used to measure P-gp expression in cell samples. Quantifying P-gp is a major challenge in oncology as its overexpression in many cancer cells results in Multidrug Resistance (MDR) associated with chemotherapy failure. To develop the method reported herein, both sample preparation and analysis parameters were investigated.
View Article and Find Full Text PDFMikrochim Acta
January 2025
Guizhou Province, Qianzhi Mingguang Soaphorn Rice Processing Base, Zhijin County, Maochang Town, Bijie CityBijie City, 552103, China.
A smartphone-based non-invasive method was developed for salivary uric acid detection using Gleditsia Sinensis carbon dots (GS-CDs). The GS-CDs synthesized by the one-pot hydrothermal method emitted blue fluorescence at a maximum excitation wavelength of 350 nm and had good fluorescence stability in the presence of different ions, while showing selectivity to uric acid solution. The ability of uric acid (UA) to quench the fluorescent substances present in the GS-CDs, was confirmed through HPLC-FLD and LC-MS, FTIR and XPS.
View Article and Find Full Text PDFJ Chromatogr Sci
January 2025
Faculty of Pharmacy, Department of Analytical Chemistry, Istanbul Health and Technology University, Istanbul 34469, Turkey.
This study presents a combination of High Performance Liquid Chromatography (HPLC) and ultraviolet (UV) detection that provides the quantification of agnuside in human plasma specimens. Reverse-phase chromatographic separation was carried out with C18 column (150 mm × 4.6 mm × 5 μm), at 25°C with isocratic elution of the mobile phase containing methanol: 0.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
Department of Biosciences and Biomedical Engineering, Indian Institute of Technology Indore, Simrol, Khandwa Road, Indore, Madhya Pradesh, 453552, India.
Background: The demand for sustainable energy solutions has increased interest in natural microalgal dyes as photosensitizers in dye-sensitized solar cells (DSSCs). This study addresses the critical issue of maximizing dye integrity and yield during extraction, particularly the degradation that occurs at temperatures above 60 °C. Our investigation of dye extraction from Asterarcys quadricellulare and Scenedesmus sp.
View Article and Find Full Text PDFIran J Pharm Res
August 2024
Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou Province, China.
, a traditional Miao medicine, is commonly used by the renowned national-level Chinese Traditional Medicine practitioner Zhengshi Wu for the treatment of diarrhea due to its strong antioxidative, anti-inflammatory, and antidiarrheal effects. This study aimed to establish a high-performance liquid chromatography (HPLC) fingerprint for to provide new evidence and technical means for the scientific evaluation and effective quality control of . The procedure involved isolation with a Nano ChromCore C18 column (250 mm × 4.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!