A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection and Hemodynamic Evaluation of Flap Fenestrations in Type B Aortic Dissection with 4D Flow MRI: Comparison with Conventional MRI and CTA. | LitMetric

Purpose: The purpose of this study was to compare dissection flap fenestration visualization between 4D flow MRI, clinical MRI/MRA, and clinical CTA studies and describe the presence of hemodynamically active fenestration flow using 4D flow.

Materials And Methods: Nineteen patients with type B dissection (age: 57±5 years) who had undergone standard of-care MRI/MRA of the chest including 4D flow MRI were retrospectively identified. Fourteen of the 19 patients also had CTA performed within 2 years of the MRI/MRA study with no interval surgery. Image review was performed independently by two radiologists. The number of fenestrations (including entry and exit tears), location, and flow directionality were recorded. Differences in the rate of detection between techniques was assessed using a Wilcoxon signed rank test.

Results: 4D flow detected more fenestrations relative to MRI/MRA [rev 1: +3 (10%), rev 2: +5 (20%)]. There were similar numbers of fenestrations detected by 4D flow relative to CTA [rev 1: +1 (4%), rev 2: -3 (-12%)]. MRI/MRA detected fewer fenestration relative to CTA in this cohort [rev 1: -6 (-24%), rev 2: -5 (-19%)]. No differences were significant. Combining 4D flow and MRI/MRA resulted in additional fenestration detection. Most fenestrations demonstrated biphasic flow over the cardiac cycle (flow entering false lumen in systole and exiting during diastole, rev 1:18/33, rev 2: 16/30).

Conclusions: 4D flow MRI can detect small flap fenestration in type B dissection patients while providing additional information about flow through fenestrations throughout the cardiac cycle relative to CTA and conventional MRI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6784318PMC
http://dx.doi.org/10.1148/ryct.2019180009DOI Listing

Publication Analysis

Top Keywords

flow mri
16
flow
12
relative cta
12
conventional mri
8
flap fenestration
8
type dissection
8
cardiac cycle
8
fenestrations
6
mri
6
cta
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!