A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preparation and application of a highly sensitive conjugated polymer-copper (Ⅱ) composite fluorescent sensor for detecting hydrazine in aqueous solution. | LitMetric

Preparation and application of a highly sensitive conjugated polymer-copper (Ⅱ) composite fluorescent sensor for detecting hydrazine in aqueous solution.

Talanta

Department of Analytical Chemistry, College of Chemistry, Jilin University, Jiefang 2519, Changchun, 130021, China. Electronic address:

Published: January 2020

At first, a conjugated polymer (poly(2,5-bis(4-(bis(pyridin-2-ylmethyl)amino) butoxyl)-1,4-Phenylethynylene-1,4-poly(phenylene ethynylene), PPE-DPA) was synthesized based on our earlier report. In this work, a highly selective and sensitive composite fluorescent sensor (PPE-DPA-Cu), which was PPE-DPA complexed with copper ions, has been developed and used to measure trace amounts of hydrazine in environmental water samples. The experiment conditions were investigated. Under optimized conditions, the sensor shows satisfactory detection performance, which can highly sensitively detect hydrazine with a linear range of 0-70 nmol L and detection limit as low as 5.4 × 10 mol L (S/N = 3). Meanwhile, the sensor exhibits high selectivity and strong anti-interference ability for various cations, anions, common reducing agents and organic amines. This sensor has been applied to detect hydrazine in the real water samples, and the recovery of hydrazine was 92.3%-112.0% after added standard solution of hydrazine. Satisfactory results indicate that the sensor is expected to be utilized for quantitative detection of hydrazine in environmental samples.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2019.120203DOI Listing

Publication Analysis

Top Keywords

composite fluorescent
8
fluorescent sensor
8
hydrazine environmental
8
water samples
8
detect hydrazine
8
hydrazine
7
sensor
6
preparation application
4
application highly
4
highly sensitive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!