Rapid and effective osseointegration, as a critical factor in affecting the success rate of titanium (Ti) implants in orthopedic applications, is significantly affected by their surface microstructure and chemical composition. In this work, surface microgrooved Ti-6Al-4V alloys with graphene oxide coating (Ti-G-GO) were fabricated by a combination of laser processing and chemical assembly techniques. The osteogenic capability in vitro and new bone formation in vivo of the implants were systematically investigated, and biomechanical pull-out tests of the screws were also performed. First, in vitro studies indicated that the optimal microgroove width of the titanium alloy surface was 45 μm (Ti-G), and the optimum GO concentration was 1 mg/mL. Furthermore, the effects of the surface microstructure and GO coating on the in vitro bioactivity were investigated through culturing bone marrow mesenchymal stem cells (BMSCs) on the surface of titanium alloy plates. The results showed that the BMSCs cultured on the Ti-G-GO group exhibited the best adhesion, proliferation, and differentiation, compared with that on the Ti-G and Ti groups. Micro-computed tomography evaluation, histological analysis, and pull-out testing demonstrated that both Ti-G and Ti-G-GO implants had the higher osseointegration than the untreated Ti implant. Moreover, the osteogenic capability of the Ti-G-GO group appeared to be superior to that of the Ti-G group, which could be attributed to the improvement of surface wettability and apatite formation by the GO coatings. These results suggest that the combination of the microgroove structure and GO coatings exhibits considerable potential for enhancing the surface bioactivation of materials, and the combination modification is expected to be used on engineered titanium alloy surfaces to enhance osseointegration for orthopedic applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acsami.9b12733 | DOI Listing |
Sci Rep
January 2025
Department of Materials Technologies, Faculty of Materials Engineering, Silesian University of Technology, 44-100, Gliwice, Poland.
MethodsX
December 2024
Department of Mechanical Engineering, Mepco Schlenk Engineering College, Sivakasi 626005, Tamil Nadu, India.
This paper provides a thorough analysis of recent advancements and emerging trends in the integration of metal additive manufacturing (AM) within orthopedic implant development. With an emphasis on the use of various metals and alloys, including titanium, cobalt-chromium, and nickel-titanium, the review looks at their characteristics and how they relate to the creation of various orthopedic implants, such as spinal implants, hip and knee replacements, and cranial-facial reconstructions. The study highlights how metal additive manufacturing (AM) can revolutionize the field by enabling customized implant designs that take patient anatomical variances into account.
View Article and Find Full Text PDFSci Rep
January 2025
Udmurt Federal Research Center of the Ural Branch of RAS, Baramzina str. 34, Izhevsk, 426067, Russia.
Ultrasound can improve the quality of finished products by reducing porosity and enhancing microstructure in selective laser melting, directed energy deposition, and laser beam welding. This study evaluates the efficiency of ultrasound produced by a pulsed laser via the optoacoustic effect. A quantitative model of collapse of vapor-gas bubbles has been developed under the conditions of ultrasonic treatment at near resonance frequencies.
View Article and Find Full Text PDFUltrason Sonochem
January 2025
State Key Laboratory of Precision Manufacturing for Extreme Service Performance, Central South University, Changsha 410083, China; Light Alloy Research Institute, Central South University, Changsha 410083, China.
The chemical corrosion of the TC4 radiation rod surface (TRRS) during the ultrasonic casting process has the potential to significantly impair the smooth conduction of ultrasonic waves. However, in the later stages of corrosion, a self-protected structure (TSPS) emerges under the ultrasonic cavitation effect, which serves to impede the chemical corrosion of the TRRS and markedly reduce the rate of mass loss of the radiation rod. This ensures the smooth ultrasonic conduction of the radiation rod during operation.
View Article and Find Full Text PDFClin Biomech (Bristol)
January 2025
Ohio State University Wexner Medical Center, Department of Orthopaedics, Columbus, OH, USA. Electronic address:
Background: Low back pain affects over 80 % of adults, with sacroiliac joint dysfunction accounting for 15-30 % of these cases. Sacroiliac fusion is a surgical procedure for refractory joint pain. While the biomechanics of the joint and its fusion relative to the spinal column are well-known, the hip-spine relationship post-fusion remains unclear.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!