Novel heart rate variability index for wrist-worn wearable devices subject to motion artifacts that complicate measurement of the continuous pulse interval.

Physiol Meas

Department of Medical and Mechatronics Engineering, Soonchunhyang University, 22 Sunchumhyang-ro, Sinchang-myeon, Asan, Chungnam 31538, Republic of Korea.

Published: November 2019

Objective: Wearable health monitoring devices have recently become popular, but they can still only measure the average heart rate. Heart rate variability (HRV) is known to represent changes in the autonomic nervous system and analysis of HRV has the potential to be used for monitoring various wellness-related parameters such as sleep or stress. HRV analysis requires accurate measurement of the heartbeat interval. In wearable devices, it is difficult to accurately measure the heartbeat interval due to motion noise. In this paper we propose a new method for performing HRV analysis on photoplethysmographic (PPG) signals corrupted by motion artifacts measured at the wrist.

Approach: A frequency-tracking algorithm based on the oscillator-based adaptive notch filter was used to measure instantaneous heart rate. The algorithm consists of a time-varying bandpass filter for enhancing the heartbeat signal and an adaptive mechanism for tracking heart rate frequency. By optimizing the filter bandwidth and forgetting factor of the adaptive mechanism, the frequency-tracking algorithm better reflects the variability of instantaneous heart rate. The new HRV index was calculated as the standard deviation of the heartbeat interval data converted using the heart rate estimated by the frequency-tracking algorithm. In order to verify the effectiveness of the proposed index, the new HRV index calculated for each sleep stage was compared with SDNN, the standard deviation of the heartbeat interval, which was calculated using simultaneous electrocardiogram measurements. In addition, changes in SDNN and the new index were compared during a socially evaluated speech task. Finally, the relationship between the new index and SDNN was compared with the data collected during daily activities over a 24 h period.

Main Results: Experimental results showed that statistically significant changes in HRV could be monitored in different sleep stages using the proposed method. In addition, when subjects were stressed by a socially evaluated speech task, significant reduction in HRV was observed using the proposed method. Finally, HRV values measured during daily activities over a 24 h period showed a high correlation coefficient of 0.812 with reference HRVs.

Significance: The new HRV index calculated by the proposed method is expected to be an effective new solution for noisy PPG signals.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6579/ab4c28DOI Listing

Publication Analysis

Top Keywords

heart rate
28
heartbeat interval
16
frequency-tracking algorithm
12
hrv calculated
12
proposed method
12
hrv
10
rate variability
8
wearable devices
8
motion artifacts
8
hrv analysis
8

Similar Publications

Characteristics of patients with undiagnosed stage 3 chronic kidney disease: results from an observational study (REVEAL-CKD) in China.

Lancet Reg Health West Pac

January 2025

Division of Nephrology, National Clinical Research Centre for Kidney Disease, State Key Laboratory of Organ Failure Research, Nanfang Hospital, Southern Medical University, Guangzhou, China.

Background: Early diagnosis of chronic kidney disease (CKD) is crucial for timely intervention to delay disease progression and improve patient outcomes. However, data for clinical characteristics of Chinese patients with undiagnosed, early-stage CKD are lacking.

Methods: REVEAL-CKD is a multinational, observational study using real-world data in selected countries to describe factors associated with undiagnosed stage 3 CKD, time to diagnosis, and CKD management post diagnosis.

View Article and Find Full Text PDF

Background: Cardiac autonomic neuropathy (CAN) is a significant complication in chronic kidney disease (CKD), leading to increased morbidity and mortality. Early detection is essential for managing CKD patients effectively, especially those on hemodialysis. This study evaluated the prevalence CAN in CKD and diagnostic accuracy of Bellavere's Score in predicting CAN in CKD patients, including those undergoing hemodialysis.

View Article and Find Full Text PDF

Objective: To evaluate the efficacy of supra-inguinal fascia iliaca compartment block (S-FICB) in patients undergoing proximal femoral nail antirotation (PFNA) internal fixation surgery for intertrochanteric fracture (ITF).

Methods: Retrospective analysis of 95 patients with ITF undergoing PFNA internal fixation surgery in the First People's Hospital of Yong Kang from March 2021 to August 2023 was performed. Among them, 49 patients received general anesthesia (GA; GA group) and 46 patients received S-FICB combined with general anesthesia (S-FICB group).

View Article and Find Full Text PDF

Background And Aims: When dealing with severely calcified lesions in endovascular therapy (EVT) for lower extremity artery disease (LEAD), navigating through severely calcified chronic total occlusion (CTO) using hard-tip guidewires can be challenging. To address this issue, we employed a novel highly intensive penetration (HIP) technique. This technique involves modifying the tail of a 0.

View Article and Find Full Text PDF

Background: Previous research has demonstrated that exposure to individual heavy metals elevates the incidence rate of congenital heart defects (CHDs). However, there is a paucity of data concerning the relationship between combined exposure to multiple heavy metals and the occurrence of CHDs. This study seeks to investigate the association between combined heavy metal exposure in pregnant women and the incidence of CHDs in their offspring in Lanzhou, China.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!