A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of the Bruder moist heat eye compress on contact lens discomfort in contact lens wearers: An open-label randomized clinical trial. | LitMetric

The purpose of this study was to investigate the effect of the Bruder Moist Heat Compress on contact lens (CL) discomfort in subjects with contact lens-related dry eye (CLDE). This was a 4-week, single-center, three-arm, randomized, open-label clinical trial in subjects diagnosed with CLDE using the Contact Lens Dry Eye Questionnaire. Fifty-one CL wearers were randomized to one of three treatment groups: application of the Bruder Compress twice a day, Bruder Compress once a day, or warm washcloth used for ten minutes twice a day without reheating. Subject diaries were monitored for compliance and collected data on daily CL comfort upon awakening and throughout the afternoon. Clinical assessments included tear film break-up time (TBUT), lipid layer thickness (LLT), and meibomian gland evaluation. Statistical tests included a generalized linear model and one-way analysis of variance (ANOVA) to investigate treatment effect on comfortable wear time. Fifty-one subjects (98% female) completed the study. After treatment, subjects using a washcloth reported more uncomfortable contact lens wear time on average (mean = 5.1 ± 2.8 h) when compared with subjects who had used the Bruder Compress in Group 1 (mean = 2.8 ± 1.6 h) (p = 0.02). In the Bruder Compress groups, there was a significant reduction in the blockage of meibomian glands (p < 0.01). No significant difference in uncomfortable wear time was found between subjects using the Bruder Compress twice daily versus once daily (p = 0.48). Subjects using the Bruder Compress once daily had the highest rate of compliance at 90.2% (p < 0.01). No significant improvements were observed in TBUT (p = 0.76) or LLT (p = 0.78). The Bruder Moist Heat Compress resulted in a significant improvement in comfortable CL wear time in subjects with CLDE.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clae.2019.09.005DOI Listing

Publication Analysis

Top Keywords

contact lens
20
bruder compress
16
bruder moist
8
moist heat
8
compress contact
8
lens discomfort
8
clinical trial
8
dry eye
8
compress day
8
wear time
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!