Novel Trigone-Based Sizing Method for Mitral Ring Annuloplasty.

Ann Thorac Surg

Department of Cardiovascular Surgery, Yokkaichi Municipal Hospital, Yokkaichi, Japan.

Published: May 2020

AI Article Synopsis

  • Researchers developed a new trigone-based sizing method for mitral annuloplasty in patients with mitral regurgitation (MR), focusing on setting trigones at one-quarter of the annular circumference.
  • The study involved 436 patients treated from 1999 to 2017, measuring various diameters and analyzing their impact on MR recurrence and other outcomes.
  • The method resulted in a high success rate (99%) for initial repairs, with satisfactory long-term control of MR and minimal instances of issues such as functional mitral stenosis or systolic anterior motion.

Article Abstract

Background: We devised a novel trigone-based sizing method, setting the trigones at one-quarter of the annular circumference, and used it for mitral annuloplasty in patients with mitral regurgitation (MR).

Methods: Between 1999 and 2017, 436 patients with degenerative (n = 192), nonischemic functional (n = 124), or ischemic (n = 120) MR underwent mitral valvuloplasty at our institution using an incomplete ring. The intertrigonal distance and prerepair and postrepair annular diameter were measured. Then the diameters predicted from body surface area, the intertrigonal distance, and the ratios of these diameters to observed data were computed. We investigated the influence of these measurements on MR recurrence, transmitral pressure gradient, and systolic anterior motion.

Results: Initial repair was successful in 433 patients (99%), but 3 patients with systolic anterior motion and MR required conversion to valve replacement. After 1, 5, and 10 years (mean follow-up, 6.3 years), the rate of freedom from grade 2 or higher recurrent MR was 96%, 92%, and 86% in the degenerative group, 99%, 97%, and 90% in the nonischemic functional group, and 95%, 90%, and 79%, respectively, in the ischemic group (P = .052). The observed/body surface area predicted diameter ratio was negatively correlated with the mean transmitral pressure gradient (mm Hg); 12.3 - 8.2 × (ratio) (R = -0.37, P < .001), despite a smaller ratio (<0.9) not being associated with less recurrence of MR. In the degenerative group, systolic anterior motion developed in 7 of 71 patients (10%) with an observed/intertrigonal distance predicted diameter ratio of less than 0.9 (P < .001).

Conclusions: Our trigone-based sizing method achieved satisfactory control of MR, while avoiding functional mitral stenosis and systolic anterior motion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.athoracsur.2019.08.085DOI Listing

Publication Analysis

Top Keywords

novel trigone-based
8
trigone-based sizing
8
sizing method
8
nonischemic functional
8
intertrigonal distance
8
surface area
8
transmitral pressure
8
pressure gradient
8
systolic anterior
8
mitral
4

Similar Publications

Article Synopsis
  • Researchers developed a new trigone-based sizing method for mitral annuloplasty in patients with mitral regurgitation (MR), focusing on setting trigones at one-quarter of the annular circumference.
  • The study involved 436 patients treated from 1999 to 2017, measuring various diameters and analyzing their impact on MR recurrence and other outcomes.
  • The method resulted in a high success rate (99%) for initial repairs, with satisfactory long-term control of MR and minimal instances of issues such as functional mitral stenosis or systolic anterior motion.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!