Objective: State-of-the-art invasive brain-machine interfaces (BMIs) have shown significant promise, but rely on external electronics and wired connections between the brain and these external components. This configuration presents health risks and limits practical use. These limitations can be addressed by designing a fully implantable BMI similar to existing FDA-approved implantable devices. Here, a prototype BMI system whose size and power consumption are comparable to those of fully implantable medical devices was designed and implemented, and its performance was tested at the benchtop and bedside.

Approach: A prototype of a fully implantable BMI system was designed and implemented as a miniaturized embedded system. This benchtop analogue was tested in its ability to acquire signals, train a decoder, perform online decoding, wirelessly control external devices, and operate independently on battery. Furthermore, performance metrics such as power consumption were benchmarked.

Main Results: An analogue of a fully implantable BMI was fabricated with a miniaturized form factor. A patient undergoing epilepsy surgery evaluation with an electrocorticogram (ECoG) grid implanted over the primary motor cortex was recruited to operate the system. Seven online runs were performed with an average binary state decoding accuracy of 87.0% (lag optimized, or 85.0% at fixed latency). The system was powered by a wirelessly rechargeable battery, consumed  ∼150 mW, and operated for  >60 h on a single battery cycle.

Significance: The BMI analogue achieved immediate and accurate decoding of ECoG signals underlying hand movements. A wirelessly rechargeable battery and other supporting functions allowed the system to function independently. In addition to the small footprint and acceptable power and heat dissipation, these results suggest that fully implantable BMI systems are feasible.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7271898PMC
http://dx.doi.org/10.1088/1741-2552/ab4b0cDOI Listing

Publication Analysis

Top Keywords

fully implantable
20
implantable bmi
16
bmi system
8
power consumption
8
designed implemented
8
wirelessly rechargeable
8
rechargeable battery
8
implantable
7
fully
6
bmi
6

Similar Publications

Introduction: Moderate-to-severe obstructive sleep apnea (OSA) affects a large segment of the US population and is characterized by repetitive and reversible obstruction of the upper airway during sleep. Untreated OSA is associated with increased incidence of heart attack, stroke, and motor vehicle accidents due to sleepiness. Continuous positive airway pressure is often prescribed, but most patients with OSA are nonadherent.

View Article and Find Full Text PDF

Extensive and closely coordinated remodeling processes take place in the periodontal ligament (PDL) and the adjacent bone during orthodontic tooth movement. In complex orthodontic cases, it is necessary to move teeth into an augmented bony defect, for example, in patients with cleft lip, alveolus, and palate. The important role of the PDL during tooth movement is well accepted but not fully understood.

View Article and Find Full Text PDF

Objective: For full expansion of ear reconstruction, the stability of a cartilage framework is very important. However, most techniques for framework fabrication focus on three-dimensional structure and adequate projection. Few studies are available on improving the stability of the reconstructed framework.

View Article and Find Full Text PDF

A prospectively deployed deep learning-enabled automated quality assurance tool for oncological palliative spine radiation therapy.

Lancet Digit Health

January 2025

Department of Radiation Oncology, Brigham and Women's Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Boston, MA, USA; Artificial Intelligence in Medicine (AIM) Program, Mass General Brigham, Harvard Medical School, Boston, MA, USA. Electronic address:

Background: Palliative spine radiation therapy is prone to treatment at the wrong anatomic level. We developed a fully automated deep learning-based spine-targeting quality assurance system (DL-SpiQA) for detecting treatment at the wrong anatomic level. DL-SpiQA was evaluated based on retrospective testing of spine radiation therapy treatments and prospective clinical deployment.

View Article and Find Full Text PDF

Background: Growing evidence indicates that metal implants influence the body's oxidative stress status, which in turn affects the degradation and stability of metal implants. The oxidative balance score (OBS) is a composite indicator, reflecting the overall oxidative balance of pro-and antioxidants of the human body. However, the associations between OBS and the level of metal ions on the population with metal implants remain to be elucidated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!