Purpose: The objective of this research was to elucidate the impact on the prognosis, including the survival prognosis, resulting from proton beam irradiation of an anatomic subsegment of the liver (ASPT) for the treatment of hepatocellular carcinoma (HCC).
Methods And Materials: A total of 110 patients who received a diagnosis of HCC were analyzed in this retrospective study. Definitive proton beam therapy was delivered at a dose of 76 Gy (relative biological effectiveness) in 20 fractions between January 2008 and December 2015. When the HCC widely abutted blood vessels or when multiple HCC tumors occurred within the same liver subsegment, the clinical target volume was outlined as an anatomic subsegment of the liver, according to the portal territory, containing the tumor. In the remaining cases, the clinical target volume was delineated by adding a 5-mm margin around the gross tumor volume. The overall survival (OS), progression-free survival (PFS), and local control rates and adverse events were assessed. A review of the medical charts assessed adverse events that occurred during and after the treatment and were classified according to the Common Terminology Criteria for Adverse Events version 4.0.
Results: The median follow-up duration was 36.5 months (range, 1-90.6 months). The median age of the patients was 73 years (range, 48-90 years). ASPT was performed in 31 patients (28%). Three-year OS, PFS, and local control rates were 74.2%, 40.4%, and 91.7%, respectively. Multivariate analysis identified ASPT as a factor that significantly improved PFS (P = .049) but not OS (P = .79). No association was found between ASPT and the frequency of grade ≥3 acute/late adverse events.
Conclusions: ASPT was associated with a reduction in the rate of tumor progression and no significant toxicity but was not associated with OS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prro.2019.09.012 | DOI Listing |
Sci Rep
January 2025
Nonprofitable Organization Touche NPO, Sapporo, 060-004, Japan.
In this study, we explore the structural intricacies of cellulose, a polymer composed of glucose monomers arranged in a linear chain, primarily investigated through solid-state NMR techniques. Specifically, we employ low-field proton nuclear magnetic resonance (H-NMR) to delve into the diverse hydrogen atom types within the cellulose molecule. The low-field H-NMR technique allows us to discern these hydrogen atoms based on their distinct chemical shifts, providing valuable insights into the various functional groups present in cellulose.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Biomedical and Biotechnological Sciences, University of Catania, 95123, Catania, Italy.
Recent investigations into radiation-induced side effects have focused on understanding the physiopathological consequences of irradiation on late-responding tissues like the spinal cord, which can lead to chronic progressive myelopathy. Proton therapy, an advanced radiation treatment, aims to minimize damage to healthy tissues through precise dose deposition. However, challenges remain, particularly regarding the variation in dose distribution, characterized by maximum deposition at the end of the proton range, known as the distal fall-off of a spread-out Bragg peak.
View Article and Find Full Text PDFMed Dosim
January 2025
Department of Radiation Oncology, Peking University First Hospital, Beijing, China. Electronic address:
This study presents a patient with a PET-CT detected residual lacrimal sac tumor who was treated with intensity modulated proton therapy (IMPT) and concurrent chemotherapy. The patient a 49-year-old male diagnosed with squamous cell carcinoma of the left lacrimal sac had under-went endoscopic surgery. Postoperative PET-CT implied tumor residual in the left lacrimal sac.
View Article and Find Full Text PDFPhys Med Biol
January 2025
Industrial Engineering, Universita degli Studi di Roma Tor Vergata, Via del Politecnico,1, Roma, 00133, ITALY.
The increasing interest in hadron therapy has heightened the need for accurate and reliable methods to assess radiation quality and the biological effectiveness of particles used in treatment. Microdosimetry has emerged as a key tool for this, demonstrating its potential, reliability, and suitability. In this context, solid-state microdosimeters offer technological advantages over traditional Tissue-Equivalent Proportional Counters, and recent advancements have further improved their performance and reliability.
View Article and Find Full Text PDFJ Radiat Res
January 2025
Department of Radiation Oncology, Southern Tohoku Proton Therapy Center 7-172, Yatsuyamada, Koriyama, Fukushima 963-8052, Japan.
This retrospective study aimed to compare the clinical outcomes of intensity-modulated radiation therapy (IMRT) and proton beam therapy (PBT). A total of 606 patients diagnosed with prostate cancer between January 2008 and December 2018 were included. Of these patients, 510 received PBT up to a dose of 70-78 Gy (relative biological effectiveness) and 96 patients received IMRT up to a dose of 70-78 Gy.