An evaluation of techniques used in superficial radiotherapy for non-melanoma skin cancer to replicate the planned treatment area: A prospective study.

Radiography (Lond)

Directorate of Diagnostic Radiography, University of Liverpool, Johnston Building, Brownlow Hill, L69 3GB, UK. Electronic address:

Published: November 2019

Introduction: Accuracy of superficial radiotherapy for non-melanoma skin cancer is dependent on replicating the original clinical mark-up. Responses from 18 UK Radiotherapy centres identified the four most common replication techniques; the accuracy and time-efficiency of each was evaluated, as well as participant preference and confidence.

Methods: A 2.0  cm × 2.5  cm ellipse field was drawn around the nasal ala of a surrogate patient. Templates for each replication method (1-4) were created, and skin marks removed. Twenty-five therapeutic radiographers used each method to replicate the mark-up. Measurements were recorded for lateral and longitudinal displacement, ellipse diameter and time taken. A post-study questionnaire recorded participant preference and perceived confidence.

Results: Comparison of the mean ellipse areas for methods 1-4 identified no statistically significant differences (ANOVA test; p = 0.579 to p = 0.999). Lateral and longitudinal displacements for method 1-4 showed a statistically significant difference between method 3 and each of methods 1, 2, 4 for lateral and longitudinal respectively (ANOVA; lateral: p = 0.008, p = 0.002, p = 0.05; longitudinal: p = 0.036, p = 0.000, and p = 0.000). Mean time taken was longest for method 3, and was compared using a Friedman test (p = 0.000) identifying a statistically significant difference. Twenty-two participants completed the questionnaire. 48% favoured method 2, 41% method 4. Method 3 was least favourite. A Likert scale (1-10) measured confidence. Participants had most confidence in methods 2 and 4.

Conclusion: In this study, method 3 was least accurate, most time consuming, and was least favoured by users. The clinical significance of these results will depend on the margins used in local practise.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.radi.2019.04.010DOI Listing

Publication Analysis

Top Keywords

lateral longitudinal
12
method
9
superficial radiotherapy
8
radiotherapy non-melanoma
8
non-melanoma skin
8
skin cancer
8
participant preference
8
method 1-4
8
statistically difference
8
evaluation techniques
4

Similar Publications

A Deep Learning Tool for Minimum Joint Space Width Calculation on Anteroposterior Knee Radiographs.

J Arthroplasty

January 2025

Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA; Mayo Clinic Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA. Electronic address:

Background: Minimum joint space width (mJSW) is an important continuous quantitative metric of osteoarthritis progression in the knee. The purpose of this study was to develop an automated measurement algorithm for mJSW in the medial and lateral compartments of the knee that can flexibly handle native knees as well as knees after arthroplasty.

Methods: We developed an end-to-end algorithm consisting of a deep learning segmentation model plus a computer vision algorithm to measure mJSW in the medial and lateral compartments of the knee.

View Article and Find Full Text PDF

Background: Subtotal and total glossectomies for advanced tongue cancer result in significant speech- and swallow-related morbidity, impairing quality of life. This prospective pilot study compares the safety and functional outcomes associated with using a chimeric innervated muscle and fasciocutaneous flap for soft tissue reconstruction.

Materials And Methods: A prospective, non-randomized controlled pilot study evaluated a standardized technique for tongue reconstruction using a chimeric innervated vastus lateralis muscle and anterolateral thigh fasciocutaneous flap.

View Article and Find Full Text PDF

Optical properties of InGaN/GaN red quantum well(QW) and their microcavities were studied and compared under optical pumping. Incidence of the excitation laser from the p-side was employed for both structures in order to acquire better emission characteristics. The QW structure was grown on sapphire substrate by metalorganic vapor-phase epitaxy(MOVPE) with a blue pre-layer QW.

View Article and Find Full Text PDF

Optical glass selection is an important research object in optical design, which is an important way to aberration correction. However, these methods to our knowledge either do not correct aberration well or consume too much time. To efficiently solve the apochromatic problems in optical design, this paper presents what we believe to be a novel automatic optimization method for discontinuous optical glass based on auto glass selection (AGS).

View Article and Find Full Text PDF

Purpose: To present a modified evisceration technique with a full-thickness horizontal sclerotomy and assess post-operative motility and long-term outcomes.

Methods: This is a retrospective chart review of patients who underwent evisceration with a single surgeon (TJM). The standard initial steps of evisceration were performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!