Intraocular lens (IOL) opacification is an infrequent complication of cataract surgery. Surface analysis has demonstrated that the opacification of IOLs is related to calcium or phosphate precipitation on or within the lenses, but the associated mechanisms are unknown, and the scientific literature is heterogeneous and limited to case series and retrospective studies. The purpose of this systematic review was to analyse the most frequent conditions associated with opacification of IOLs reported by studies. A search was carried out using the PubMed MEDLINE, Web of Science and Scopus databases. The quality of the studies selected was evaluated using the Pierson tool. The search provided a total of 811 articles, of which 39 were selected following the inclusion and exclusion criteria. The most common opacified lenses were hydrophilic IOLs according to our analysis. The mean time of appearance of lens opacification was 14.93 ± 17.82 months. The most frequent conditions associated with opacification of the IOLs were Descemet Stripping with Automated Endothelial Keratoplasty (DSAEK/DSEK) and diabetes mellitus (DM), followed by pars plana vitrectomy (PPV), blood hypertension (HT), and glaucoma. Concerning the quality analysis, the mean score was 7.00 ± 1.43 (scoring range from 0 to 10), indicating an acceptable quality of the case reports and retrospective studies. In conclusion, DSAEK/DSEK, DM, PPV, glaucoma and hypertension are conditions with potential risk of IOL opacification after cataract surgery, especially when implanting hydrophilic acrylic IOLs.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ceo.13650DOI Listing

Publication Analysis

Top Keywords

opacification iols
12
systematic review
8
intraocular lens
8
lens opacification
8
iol opacification
8
cataract surgery
8
retrospective studies
8
frequent conditions
8
conditions associated
8
associated opacification
8

Similar Publications

Purpose: Severely myopic eyes have been associated with high posterior capsule opacification (PCO) incidence. Although it has been reported that myopic eyes have weaker or more delayed capsule adhesion than emmetropic eyes, it is unclear whether/how dioptric power and posterior curvature of IOLs affect IOLs' affinity for the posterior lens capsule (PLC) and their PCO potential.

Methods: To investigate this, acrylic foldable IOLs with increasing dioptric power of 6.

View Article and Find Full Text PDF

This study aims to analyze the prevalence and severity of posterior capsule opacification (PCO) and glistening in a new hydrophobic biaspheric monofocal intraocular lens (IOLs) 24 months after implantation. By means of a ambispective, observational, case-control design, a total of 297 eyes from 200 cataract surgery patients were included in the study (118 females and 82 males; mean age: 72.31 ± 9.

View Article and Find Full Text PDF

Innovative Polymeric Biomaterials for Intraocular Lenses in Cataract Surgery.

J Funct Biomater

December 2024

Department of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada.

Intraocular lenses (IOLs) play a pivotal role in restoring vision following cataract surgery. The evolution of polymeric biomaterials has been central to addressing challenges such as biocompatibility, optical clarity, mechanical stability, and resistance to opacification. This review explores essential requirements for IOL biomaterials, emphasizing their ability to mitigate complications like posterior capsule opacification (PCO) and dysphotopsias while maintaining long-term durability and visual quality.

View Article and Find Full Text PDF

Scleral fixated intraocular lens techniques for the vitreoretinal surgeon: an update.

Curr Opin Ophthalmol

December 2024

Department of Research, Wills Eye Hospital, Philadelphia, PA.

Purpose Of Review: To describe recent evidence regarding surgical techniques for secondary scleral fixation of intraocular lenses (IOLs), with attention to information most relevant to the surgical practice of vitreoretinal surgeons.

Recent Findings: Recent studies have reported favorable outcomes in patients treated with scleral fixation of IOLs using Gore-Tex suture and flanged intrascleral haptic fixation (ISHF). ISHF can be achieved using trocar-cannulas or double needle-based techniques.

View Article and Find Full Text PDF

Aim: To investigate the biocompatibility and bacterial adhesion properties of light responsive materials (LRM) and analyze the feasibility and biosafety of employing LRM in the preparation of accommodative intraocular lenses (AIOLs).

Methods: Employing fundamental experimental research techniques, LRM with human lens epithelial cells (hLECs) and human retinal pigment epithelium cells (ARPE-19 cells) were co-cultured. Commercially available intraocular lenses (IOLs) were used as controls to perform cell counting kit-8 (CCK-8), cell staining under varying light intensities, cell adhesion and bacterial adhesion experiments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!