The opioid crisis and emergence of fentanyl, fentanyl analogues, and other synthetic opioids has highlighted the need for sensitive and robust detection for interdiction at screening points, notably vehicles at border crossings and packages at postal facilities. This work investigates the discriminative potential, sensitivity and specificity, of ion mobility spectrometry (IMS) for the detection of fentanyl and fifteen (15) fentanyl-related compounds (analogues, other opioids, and metabolites) relative to confounding environmental interferents. The environmental background interferent levels, frequency and intensity, were derived from over 10 000 screening samples collected from delivery vehicles entering a federal site. A receiver operating characteristic (ROC) curve methodology was employed to quantify the relationship between sensitivity and specificity for these target compounds on two instruments/configurations. These instrument configurations differed in desorption and drift tube temperatures, reactant ion dopant chemistry, and analysis time. This work identified reduced mobility areas of high interference that resulted in increased false positive rates (FPR), effectively reducing sensitivity (true positive rate: TPR) in those regions. Except for a few target compounds on either of the instruments that exhibited elevated FPRs, detection of fentanyl and fentanyl-related species was achieved at single to tens of nanograms with ≥90% TPR and ≤2% FPR. This work established the importance of systematic environmental background characterization at each specific screening setting in evaluating a platform's true performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7008973PMC
http://dx.doi.org/10.1039/c9an01771bDOI Listing

Publication Analysis

Top Keywords

detection fentanyl
12
discriminative potential
8
ion mobility
8
mobility spectrometry
8
fentanyl fentanyl
8
fentanyl analogues
8
relative confounding
8
confounding environmental
8
environmental interferents
8
sensitivity specificity
8

Similar Publications

Epidemiology of New Psychoactive Substances in Relation to Traditional Drugs of Abuse in Clinical Oral Fluid Samples.

Basic Clin Pharmacol Toxicol

February 2025

Department of Laboratory Medicine, Institute of Biomedicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.

New psychoactive substances (NPS) are health-hazardous through unpredictable toxicity and effects and largely unknown epidemiology, motivating studies of the latter. Up to 138 NPS were retrospectively identified using liquid chromatography-high resolution mass spectrometry data from all 34 183 oral fluid drug samples collected in one Swedish health care region 2019-2020 representing 9468 psychiatric and addiction care patients. In total, 618 findings representing 58 NPS were detected in 481 samples from 201 patients.

View Article and Find Full Text PDF

Human nails have recently become a sample of interest for toxicological purposes. Multiple studies have proven the ability to detect various analytes within the keratin matrix of the nail. The analyte of interest in this study is fentanyl, a highly dangerous and abused drug in recent decades.

View Article and Find Full Text PDF

Substructure-Specific Antibodies Against Fentanyl Derivatives.

ACS Nano

January 2025

School of Chemistry and Biochemistry, Georgia Institute of Technology, 901 Atlantic Dr., Atlanta, Georgia 30332, United States.

Structural variants of the synthetic opioid fentanyl are a major threat to public health. Following an investigation showing that many derivatives are poorly detected by commercial lateral flow and related assays, we created hapten conjugate vaccines using an immunogenic virus-like particle carrier and eight synthetic fentanyl derivatives designed to mimic the structural features of several of the more dangerous analogues. Immunization of mice elicited strong antihapten humoral responses, allowing the screening of hundreds of hapten-specific hybridomas for binding strength and specificity.

View Article and Find Full Text PDF

Introduction: As illicit drug manufacturers find new ways to market their products and increase their profit margins, multiple contaminants have found their way into the illicit drug supply. The newest addition, xylazine, also known as "tranq," has spread through the city of Philadelphia and has recently been gaining ground across the United States, including in the state of Florida.

Case Presentation: This case describes a 37-year-old male with a significant past psychiatric history of severe polysubstance intravenous (IV) use, including fentanyl and methamphetamine.

View Article and Find Full Text PDF

Serially coupled columns enhance rapid separation and predictive interaction understanding of 93 fentanyl analogs.

Anal Chim Acta

January 2025

College of Pharmacy, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul, 06974, Republic of Korea. Electronic address:

Background: The simplicity of synthesis methods has facilitated the illegal manufacture of various fentanyl analogs, leading to numerous fatal overdoses worldwide, particularly in North America. Fentanyl analogs with similar structures are difficult to distinguish due to their fragmentation patterns, making separation using chromatography essential. Additionally, because fentanyl analogs are lethal even in trace amounts, they are easily smuggled, and commonly used fentanyl test strips often fail to detect them due to their low sensitivity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!