Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Although newer needle designs are thought to improve diagnostic outcomes of endoscopic ultrasound-guided fine-needle biopsy, there is limited evidence on their diagnostic performance. The aim of this meta-analysis was to provide a pooled estimate of the diagnostic performance and safety profile of Franseen and Fork-tip fine-needle biopsy needles. Computerized bibliographic search on the main databases was performed through March 2019. The primary endpoint was sample adequacy. Secondary outcomes were diagnostic accuracy, optimal histological core procurement, mean number of needle passes, pooled specificity and sensitivity. Safety data were also analyzed. Twenty-four studies with 6641 patients were included and pancreas was the prevalent location of sampled lesions. Overall sample adequacy with the two newer needles was 94.8 % (93.1 % - 96.4 %), with superiority of Franseen needle over Fork-tip (96.1 % versus 92.4 %, < 0.001). Sample adequacy in targeting pancreatic masses was 95.6% and both needles produced results superior to fine-needle aspiration (FNA) (odds ratio 4.29, 1.49 - 12.35 and 1.79, 1.01 - 3.19 with Franseen and Fork-tip needle, respectively). The rate of histological core procurement was 92.5%, whereas diagnostic accuracy and sensitivity were 95 % and 92.8 %, again with no difference between the two needles. Number of needle passes was significantly lower in comparison to FNA (mean difference: -0.42 with Franseen and -1.60 with Fork-tip needle). No significant adverse events were registered. Our meta-analysis speaks in favor of use of newer biopsy needles as a safe and effective tool in endoscopic ultrasound-guided tissue acquisition.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6773615 | PMC |
http://dx.doi.org/10.1055/a-0982-2997 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!