Background: The course of lung function decline in amyotrophic lateral sclerosis (ALS) and the effect of noninvasive positive-pressure ventilation (NIPPV) on that decline are uncertain. We sought to model lung function decline, determine when NIPPV is initiated along that course, and assess its impact on the course of decline.
Methods: An observed sigmoid pattern of forced vital capacity decline was reproduced with a four-parameter nonlinear mixed-effects logistic model.
Results: Analyses were performed on 507 patients overall and in 353 patients for whom a determination of adherence to NIPPV was ascertained. A sigmoid bi-asymptotic model provided a statistical fit of the data and showed a period of stable vital capacity, followed by an accelerated decline, an inflection point, then a slowing in decline to a plateau. By the time NIPPV was initiated in accordance with reimbursement guidelines, vital capacity had declined by ≥85% of the total range. Nearly half of the total loss of vital capacity occurred over 6.2 months centred at an inflection point occurring 17 months after disease onset and 5.2 months before initiation of NIPPV at a vital capacity of about 60%. Fewer bulbar symptoms and a faster rate of decline of lung function predicted adherence to NIPPV, but the intervention had no impact on final vital capacity.
Conclusions: In patients with ALS, vital capacity decline is rapid but slows after an inflection point regardless of NIPPV. Initiating NIPPV along reimbursement guidelines occurs after ≥85% of vital capacity loss has already occurred.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6759589 | PMC |
http://dx.doi.org/10.1183/23120541.00044-2019 | DOI Listing |
ACS Nano
January 2025
Battery and Electrochemistry Laboratory (BELLA), Institute of Nanotechnology, Karlsruhe Institute of Technology (KIT), Kaiserstr. 12, Karlsruhe 76131, Germany.
Improving interfacial stability between cathode active material (CAM) and solid electrolyte (SE) is vital for developing high-performance all-solid-state batteries (ASSBs), with compatibility issues among the cell components representing a major challenge. CAM surface coating with a chemically inert ion conductor is a promising approach to suppress side reactions occurring at the cathode interfaces. Another strategy to mitigate mechanical degradation involves utilizing single-crystalline particle morphologies.
View Article and Find Full Text PDFScand J Clin Lab Invest
January 2025
Centre for Physical Activity Research, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
The objective of the current review was to identify whether clinically established lung function metrics of ventilatory and diffusion capacity obtained by standardised methodology are consistent with superior lung function in athletes, and whether this is related to maximal oxygen uptake (V̇O). Three independent reviewers performed a literature search in PubMed, Scopus, and reference screening. Data was extracted and analysed according to a predefined strategy.
View Article and Find Full Text PDFAnal Methods
January 2025
Air Resource, Environmental Resource Planning and Management, CSIR-National Environmental Engineering Research Institute (CSIR-NEERI), Nehru Marg, Nagpur, 440020, India.
Dioxins rank among the most hazardous persistent organic pollutants, presenting a serious threat due to their long environmental lifespan and capacity for bioaccumulation. This comprehensive review delves into the historical, chemical, and toxicological aspects of dioxins, spotlighting significant incidents such as the Seveso disaster and the repercussions of Agent Orange. The review offers a thorough analysis of the sources of dioxin formation, encompassing natural occurrences like volcanic eruptions and wildfires, alongside man-made activities such as industrial combustion and waste incineration.
View Article and Find Full Text PDFClin Oral Implants Res
January 2025
Etiology and Therapy of Periodontal and Periimplant Diseases (ETEP) Research Group, Faculty of Dentistry, Complutense University, Madrid, Spain.
Aim: To evaluate in vitro the antibacterial efficacy and cytocompatibility of different implant-decontamination methods, using both 2D and 3D peri-implant mucosa models.
Methods: Four decontamination methods [chlorhexidine (CHX), electrolytic treatment (GS), curcumin (CUR), xanthohumol (XN)] were compared in four independent experiments, three with a 2D peri-implant mucosa model on titanium surfaces and another on a 3D peri-implant mucosa model. These decontamination procedures were tested for their antibacterial effect using a multispecies biofilm model with Streptococcus oralis, Actinomyces naeslundii, Veillonella dispar, and Porphyromonas gingivalis for 24 h.
Indian J Occup Environ Med
December 2024
Department of Electronics, Sri Venkateswara College, University of Delhi, New Delhi, India.
Introduction: Construction sites generate high levels of air pollution, contributing to more than 4% of particulate matter in the atmosphere. Literature indicates that on-site pollution is an important factor that contributes to lung impairments in construction workers. Chronic obstructive pulmonary disease (COPD) and acute respiratory distress syndrome (ADRS) are known to be exacerbated because of exposure to a variety of construction pollutants mainly particulate matter (PM10, PM2.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!