A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of tension band wiring and other tibial tuberosity advancement techniques for cranial cruciate ligament repair: an experimental study. | LitMetric

Background: Cranial cruciate ligament (CCL) rupture is one of the most common causes of limb lameness in dogs. Surgical techniques based on tibial osteotomies such as tibial plateau leveling osteotomy and tibial tuberosity advancement are used to eliminate dynamic thrust. Tibial tuberosity advancement (TTA) uses an osteotomy fixated by cage, plates, forks and screws to change the relationship of the patellar tendon and tibial plateau angle. Tension band wiring technique is one of the most common surgical methods used to treat a tension fracture and remains the gold standard for the treatment of tibial tuberosity fractures. In this study, we compared experimentally the biomechanical effect of application of tension band wiring compared to other techniques for the fixation of the TTA osteotomy. The techniques compared to are standard commercially available systems for TTA fixation.

Results: Tension band wiring (TBW) presented the higher resistance to failure compared to all the other surgical procedures, with the highest values found in the TBW group with 1.47 ± 0.07 N and the lowest in the TTA cage (0.82 ± 0.08) and TTA-2 (0.85 ± 0.06) groups with statistically significant differences in all cases (P < 0.001). TTA rapid and TTA plate groups exhibited a similar strength, and same happened between TTA-2 and TTA cage groups. All the other comparisons by pair were significantly different with P < 0.001.

Conclusions: Results suggest that fixating the osteotomy with tension band wiring increases the strength of the fixation and decrease the risk of implant failure. Further clinical studies are needed to demonstrate in vivo reliability and to test different variables such as size and weight of dogs. These results could have important clinical implications in the treatment of CCL ruptures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6775671PMC
http://dx.doi.org/10.1186/s13028-019-0481-1DOI Listing

Publication Analysis

Top Keywords

tension band
16
band wiring
16
tibial tuberosity
16
tuberosity advancement
12
cranial cruciate
8
cruciate ligament
8
tibial plateau
8
tta osteotomy
8
tibial
7
comparison tension
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!