This study explores the possibility of measuring the dynamics of proteins in solution using X-ray photon correlation spectroscopy (XPCS) at nearly diffraction-limited storage rings (DLSRs). We calculate the signal-to-noise ratio (SNR) of XPCS experiments from a concentrated lysozyme solution at the length scale of the hydrodynamic radius of the protein molecule. We take into account limitations given by the critical X-ray dose and find expressions for the SNR as a function of beam size, sample-to-detector distance and photon energy. Specifically, we show that the combined increase in coherent flux and coherence lengths at the DLSR PETRA IV yields an increase in SNR of more than one order of magnitude. The resulting SNR values indicate that XPCS experiments of biological macromolecules on nanometre length scales will become feasible with the advent of a new generation of synchrotron sources. Our findings provide valuable input for the design and construction of future XPCS beamlines at DLSRs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6760446 | PMC |
http://dx.doi.org/10.1107/S2052252519008273 | DOI Listing |
J Biophotonics
January 2025
Center for Photonic Science and Engineering, Skolkovo Institute of Science and Technology, Moscow, Russia.
Skin homeostasis is strongly dependent on its hydration levels, making skin water content measurement vital across various fields, including medicine, cosmetology, and sports science. Noninvasive diagnostic techniques are particularly relevant for clinical applications due to their minimal risk of side effects. A range of optical methods have been developed for this purpose, each with unique physical principles, advantages, and limitations.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Division of Nephrology, Department of Internal Medicine, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpaşa, Istanbul 34098, Turkey.
: Bone and mineral disease (BMD) is a prevalent complication of advanced chronic kidney disease (CKD). The risk of fractures can be assessed via dual-energy X-ray absorptiometry (DXA) and quantitative computed tomography (QCT). This study aims to evaluate the effectiveness of two imaging modalities in identifying bone mineral status in individuals with pre-dialysis chronic renal disease and to assess their correlation with bone turnover markers.
View Article and Find Full Text PDFMicromachines (Basel)
December 2024
Northwest Institute of Nuclear Technology, Xi'an 710024, China.
In this paper, a silicon carbide (SiC) phototransistor based on an open-base structure was fabricated and used as a radiation detector. In contrast to the exposed and thin sensitive region of traditional photo detectors, the sensitive region of the radiation detector was much thicker (30 μm), ensuring the high energy deposition of radiation particles. The response properties of the fabricated SiC npn radiation detector were characterized by high-energy X-ray illumination with a maximum X-ray photon energy of 30 keV.
View Article and Find Full Text PDFInt J Environ Res Public Health
December 2024
Microbiology Department, Vall d'Hebron University Hospital, Vall d'Hebron Research Institute (VHIR), 08035 Barcelona, Spain.
The gold standard diagnosis for malaria is the microscopic visualization of blood smears to identify parasites, although it is an expert-dependent technique and could trigger diagnostic errors. Artificial intelligence (AI) tools based on digital image analysis were postulated as a suitable supportive alternative for automated malaria diagnosis. A diagnostic evaluation of the AI-based system was conducted in the reference laboratory of the International Health Unit Drassanes-Vall d'Hebron in Barcelona, Spain.
View Article and Find Full Text PDFDiagnostics (Basel)
January 2025
Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, CH-8091 Zurich, Switzerland.
: Diffuse myocardial fibrosis and altered deformation are relevant prognostic factors in aortic stenosis (AS) patients. The aim of this exploratory study was to investigate the relationship between myocardial strain, and myocardial extracellular volume (ECV) in patients with severe AS with a photon-counting detector (PCD)-CT. : We retrospectively included 77 patients with severe AS undergoing PCD-CT imaging for transcatheter aortic valve replacement (TAVR) planning between January 2022 and May 2024 with a protocol including a non-contrast cardiac scan, an ECG-gated helical coronary CT angiography (CCTA), and a cardiac late enhancement scan.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!