A micro liquid-liquid extraction has been applied to sample preparation in the current authorized method for clopyralid in compost. The method rendered matrix effects practically negligible during determination with ultraperformance liquid chromatography-electrospray ionization tandem mass spectrometry with an improved limit of quantification of 0.7 µg/kg dry weight. Moreover, it had good accuracy and reproducibility. Therefore, the method is proposed as a highly effective routine analytical technique for investigating the actual status of clopyralid residue in compost.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6753256 | PMC |
http://dx.doi.org/10.1584/jpestics.D19-023 | DOI Listing |