TomoTherapy is a modern radiation treatment technique in which intensity-modulated radiation therapy (IMRT) is delivered in helical fashion. A two-dimensional (2D) array which has been existing for IMRT patient-specific quality assurance (PSQA) verifications for many years is I'MatriXX. Our objectives were to validate this I'MatriXX and to evaluate it for different patient sites and fractionation schedules of TomoTherapy treatment. Twenty-five plans were created with virtual target for different possible pitch values and field widths for validation. Gamma index criteria of 3%/2% dose differences and 3/2 mm distance to agreement were used. QA plans of 26 different treatment sites and different fractionation schedules were used. Results indicated that the matrix response is independent of field width, pitch, and modulation factor of TomoTherapy with 3%, 3 mm criteria. High passing rate ranging from 99.7% to 90.7% was observed for selected patient plans. We found that I'MatriXX 2D array can be utilized for easy and quick TomoTherapy PSQA.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6764175 | PMC |
http://dx.doi.org/10.4103/jmp.JMP_11_19 | DOI Listing |
Radiol Phys Technol
March 2024
School of Advanced Sciences, Vellore Institute of Technology, Vellore, 632014, India.
An accurate and reliable patient-specific quality assurance (PSQA) is crucial to ensure the safety and precision of Stereotactic body radiation therapy (SBRT) in treating Hepatocellular carcinoma (HCC). This study examines the effectiveness of a novel hybrid 3D-printed hybrid coaxial cylindrical phantom for PSQA in the SBRT of HCC. The study compared three different point dose verification techniques for PSQA: a traditional solid water phantom, two dimensional detector array I'MatriXX, and a newly developed hybrid 3D-printed phantom.
View Article and Find Full Text PDFJ Med Phys
January 2019
Department of Radiotherapy, Basavatarakam Indo American Cancer Hospital and Research Institute, Hyderabad, Telangana, India.
TomoTherapy is a modern radiation treatment technique in which intensity-modulated radiation therapy (IMRT) is delivered in helical fashion. A two-dimensional (2D) array which has been existing for IMRT patient-specific quality assurance (PSQA) verifications for many years is I'MatriXX. Our objectives were to validate this I'MatriXX and to evaluate it for different patient sites and fractionation schedules of TomoTherapy treatment.
View Article and Find Full Text PDFJ Med Phys
October 2014
Department of Radiation Oncology, Acharya Tulsi Regional Cancer Treatment and Research Institute, Sardar Patel Medical College and Associated Group of Hospitals, Bikaner, Rajasthan, India.
Purpose: To study the impact of different smoothing parameters on IMRT plan quality and deliverabilityMethods: Five previously treated patients of carcinoma cervix were chosen. Planning target volume (PTV) and organ at risk (OAR) i.e.
View Article and Find Full Text PDFRep Pract Oncol Radiother
December 2013
Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bangalore 560029, India.
Aim: To compare the measured and calculated individual and composite field planar dose distribution of Intensity Modulated Radiotherapy plans.
Materials And Methods: The measurements were performed in Clinac DHX linear accelerator with 6 MV photons using Matrixx device and a solid water phantom. The 20 brain tumor patients were selected for this study.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!