An efficient and fast dispersive magnetic solid phase extraction method was developed using MIL-101(Cr)/poly (mercaptobenzothiazole)@magnetite nanoparticles for the preconcentration and determination of nitrophenols in river and rain water samples. High-performance liquid chromatography-Ultraviolet instrument was applied for the analysis of target nitrophenols. The effect of several variables on the extraction performance was explored via design of experiment approach. Limits of detection and linear dynamic ranges were attained in the range of 0.05-0.10 µg/L and 0.2-250 µg/L, respectively. The enrichment factors were in the range of 317-363. The precision (n = 3) of dispersive magnetic solid phase extraction method was in the range of 5.3-6.8%. Eventually, the method was utilized for the analysis of target nitrophenols in river and rain water samples.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jssc.201900692DOI Listing

Publication Analysis

Top Keywords

water samples
12
dispersive magnetic
12
magnetic solid
12
solid phase
12
phase extraction
12
extraction method
8
nitrophenols river
8
river rain
8
rain water
8
analysis target
8

Similar Publications

Neglected tropical diseases (NTDs) affect over a billion people worldwide. The 2021-2030 NTD road map calls for innovative and highly efficient interventions to eliminate or significantly reduce the burden of NTDs. These include sensitive and cost-effective diagnostic techniques for disease surveillance.

View Article and Find Full Text PDF

Data on dissolved phase water concentrations of polychlorinated biphenyls (PCBs) from 32 locations across the U.S. were compiled from reports, Web sites, and peer-reviewed papers, spanning 1979-2020, resulting in 5132 individual samples.

View Article and Find Full Text PDF

Wet chemical sensors autonomously sample and analyze water using chemical assays. Their internal fluidics are not susceptible to biofouling (the undesirable accumulation of microorganisms, algae, and animals in natural waters) due to the harsh chemical environment and dark conditions; however, the sample intake and filter are potentially susceptible. This paper describes the use of copper intake filters, incorporated to prevent fouling, on two different wet chemical nitrate sensors that each use different variants of the Griess assay (in particular, different nitrate reduction steps) to quantify nitrate concentrations.

View Article and Find Full Text PDF

Alkylated polycyclic aromatic hydrocarbons (PAHs) are abundant constituents of many PAH mixtures and contribute to risk at contaminated sites. Despite their abundance, the movement of alkylated PAHs remains understudied relative to unsubstituted PAHs. In the present study, passive sampling devices were deployed in the air, water, and sediments at 11 locations across multiple seasons to capture spatial and temporal variability in the abundance and movement of alkylated PAHs at a Brownsfield creosote site in Oregon, USA.

View Article and Find Full Text PDF

Context: Historical land use is thought to have influenced plant community diversity, composition and function through the local persistence of taxa that reflect ecological conditions of the past.

Objectives: We tested for the effects of historical land use on contemporary plant species richness, composition, and ecological preferences in the grassland vegetation of Central Europe.

Methods: We analyzed 6975 vegetation plots sampled between 1946 and 2021 in dry, mesic, and wet grasslands in the borderland between Austria, the Czech Republic, and Slovakia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!