A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrocutions in free-living black-tufted marmosets (Callithrix penicillata) in anthropogenic environments in the Federal District and surrounding areas, Brazil. | LitMetric

Shrinking natural habitats exposes some non-human primates to the risk of accidents associated with electrical transmission lines. We examined dead marmosets (Callithrix penicillata) collected in the region from January 2015 to April 2018 to determine the animals' cause of death and for electrocuted animals we examined the locations the animals had died as well as the configuration of the power lines at these sites. We also recorded the sex of the animal, the body region affected, and characteristics of the injuries. We diagnosed electrocutions in 11% (n = 34) of the marmosets studied. Most of the affected animals were male (n = 22) with single or double sites of injury on the limbs. Animals were injured in urban (n = 26) and peri-urban (n = 8) areas on lower-voltage alternate current lines, and we detected no seasonality or hotspots of electrocution. Our findings suggest that movement along transmission lines composed of bundled conductors is a major factor in electrocutions of marmosets in the Federal District and surrounding areas. The planning of electrical power grid infrastructure should consider arboreal primates to prevent electrocutions.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10329-019-00760-xDOI Listing

Publication Analysis

Top Keywords

marmosets callithrix
8
callithrix penicillata
8
federal district
8
district surrounding
8
surrounding areas
8
transmission lines
8
electrocutions
4
electrocutions free-living
4
free-living black-tufted
4
marmosets
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!