An LC-MS/MS assay with a label-free internal standard for quantitation of serum cystatin C.

Anal Biochem

Department of Laboratory Medicine, Affiliated Hospital of Nantong University, Nantong, 226001, China. Electronic address:

Published: December 2019

Cystatin C is considered as an alternative to the evaluation of glomerular filtration rate. In this study, we highlighted an LC-MS/MS approach for the absolute quantitation of serum cystatin C based on label-free internal standards. A tryptic peptide (ALDFAVGEYNK) was selected as the surrogate whilst analogue (ALDFAVGEYQK) served as an internal standard. After denaturation, reduction, alkylation, digestion and concentration, the target peptides were separated on an LC column and monitored under MRM. The calibration range was from 0.25 mg/L to 15 mg/L with LLOQ of 0.05 mg/L and LOD of 0.03 mg/L, respectively. The certified reference material (ERM-DA471) was determined at 5.12 mg/L with bias of 6.57%. The recovery was between 89.68% and 92.43%. The RSD of intra- and inter-assay imprecision were both <10%. Good stability was also observed. The assay also demonstrated that the quantification of native cystatin C in human serum could be achieved using label-free internal standards. The assay was robust, cheap and sensitive.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ab.2019.113451DOI Listing

Publication Analysis

Top Keywords

label-free internal
8
internal standard
8
quantitation serum
8
serum cystatin
8
lc-ms/ms assay
4
assay label-free
4
standard quantitation
4
cystatin cystatin
4
cystatin considered
4
considered alternative
4

Similar Publications

Purpose: Understanding the molecular mechanisms of adaptive regulation in the tumor microenvironment is crucial for precision therapy in hepatocellular carcinoma (HCC). We hypothesized that cargo proteins carried by extracellular vesicles (EVs) released in a hypoxic microenvironment might promote HCC progression by remodeling tumor-associated macrophages (TAMs).

Methods: EV protein analysis by label-free proteomics mass spectrometry of HCC cell lines of different tumor grades was performed.

View Article and Find Full Text PDF

Vulnerable atherosclerotic plaques, especially hemorrhaged lesions, are the major cause of mortalities related to vascular pathologies. The early identification of vulnerable plaques helps to stratify patients at risk of developing acute vascular events. In this study, proteomics analyses of human carotid artery samples collected from patients with atheromatous plaques and complicated lesions, respectively, as well as from healthy controls were performed.

View Article and Find Full Text PDF

Combining Fundamental Kinetics and Standard Alkylation Assays to Prioritize Lead-Like KRAS G12C Inhibitors.

ACS Omega

December 2024

Department of Biochemical and Cellular Pharmacology, Genentech, Inc., South San Francisco, California 94080, United States.

We measure the fundamental rate constants of internally discovered KRAS G12C inhibitors to demonstrate how kinetic analyses can be integrated with standard biochemical and cell-based assays for more optimal biophysical compound prioritization. In this proof-of-principle study, we characterize three irreversible covalent inhibitors targeting the mutant cysteine at the switch II binding pocket. We estimate the three fundamental kinetic rate constants ( , , ) that define the contributions of affinity and inactivation to the overall alkylation rate for a more complete biophysical characterization.

View Article and Find Full Text PDF

An antibody-free bio-layer interferometry biosensor for immunoglobulin G1 detection in human serum by using molecularly imprinted polynorepinephrine.

Biosens Bioelectron

March 2025

Department of Chemistry "Ugo Schiff', University of Florence, Via della Lastruccia, 3-13, 50019, Sesto Fiorentino, Italy. Electronic address:

Bio-Layer Interferometry (BLI) has emerged as a versatile technique in affinity-based biosensing, analogous to Surface Plasmon Resonance. BLI enables real-time, label-free detection, and quantification of biomolecular interactions between an immobilized receptor and an analyte in solution. The BLI sensor comprises an optical fiber with an internal reference layer at the end and an external biocompatible layer where biological receptors are immobilized and exposed to the solution.

View Article and Find Full Text PDF

Background And Objective: Breast-conserving surgery (BCS) plays a crucial role in breast cancer treatment, with a primary focus on ensuring cancer-free surgical margins, particularly for patients undergoing neoadjuvant treatment. After neoadjuvant treatment, tumor regression can complicate the differentiation between breast cancer and adjacent tissues. Raman spectroscopy, as a rapid and non-invasive optical technique, offers the advantage of providing detailed biochemical information and molecular signatures of internal molecular components in tissue samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!