Accuracy of real-time shear wave elastography in the assessment of normal small intestine mucosa in dogs.

Pol J Vet Sci

Department and Clinic of Surgery, Faculty of Veterinary Medicine, Wroclaw University of Environmental and Life Sciences, pl. Grunwaldzki 51, 50-366 Wrocław, Poland.

Published: September 2019

The aim of the study was to assess the physiological stiffness of the normal canine jejunal mucosa based on shear wave elastography. The study was carried out on 60 dogs. In all the animals studied, the abdominal ultrasound was carried out using the SuperSonic Imagine Aixplorer system. The site of the jejunal elastography was determined using standard ultrasonography and all the measurements were carried out thrice. The stiffness of the area examined was determined during each measurement. Mean values were calculated based on the results obtained. The normal stiffness of the jejunal mucosa ranged from 1.305 kPa to 9.319 kPa (mean 5.31 ± 2.04 kPa). Based on our findings, we determined the range of normal values of the jejunal mucosal stiffness in healthy dogs. In addition, shear wave elastography was found to be safe and easy to perform. Moreover, it did not require anaesthesia or patient immobilisation for long periods.

Download full-text PDF

Source
http://dx.doi.org/10.24425/pjvs.2019.129305DOI Listing

Publication Analysis

Top Keywords

shear wave
12
wave elastography
12
jejunal mucosa
8
accuracy real-time
4
real-time shear
4
elastography
4
elastography assessment
4
normal
4
assessment normal
4
normal small
4

Similar Publications

[Value of comprehensive evaluation of bladder structure and function in children by multi-modal ultrasound].

Zhonghua Yi Xue Za Zhi

January 2025

Department of Urology, Henan Joint International Pediatric Urodynamic Laboratory, the First Affiliated Hospital of Zhengzhou University, Zhengzhou450002, China.

To comprehensively evaluate the structure and function of the bladder wall in children using multi-modal ultrasound (MMU). A total of 110 children without urinary symptoms admitted to the First Affiliated Hospital of Zhengzhou University from January 2022 to June 2023 were included prospectively. MMU was performed and the vesical volume (VV), bladder wall thickness (BWT), shear wave velocity (SWV) of the anterior wall, resistance index (RI) and vascularization index (VI) were measured in the filled and emptied bladder respectively, and the ultrasound bladder compliance (UBC) was also calculated.

View Article and Find Full Text PDF

Validation of Muscle Ultrasound Speckle Tracking and the Effect of Nordic Hamstring Exercise on Biceps Femoris Displacement.

Ultrasound Med Biol

January 2025

School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, Taipei, Taiwan ROC; Center of Physical Therapy, National Taiwan University Hospital, Taipei, Taiwan ROC. Electronic address:

Objective: This study aimed to validate the ultrasound speckle tracking (UST) algorithm, determine the optimal probe location by comparing normalized cross-correlation (NCC) values of muscle displacement at two locations (proximal vs. middle) of the biceps femoris long head (BFlh) using the UST, and investigate the effects of Nordic hamstring curl exercise (NHE) training on BFlh displacement.

Methods: UST efficacy was verified with ex vivo uniaxial testing of porcine leg muscles.

View Article and Find Full Text PDF

Joint Analysis of Cardiovascular Control and Shear Wave Elastography to Determine Carotid Plaque Vulnerability.

J Clin Med

January 2025

Operative Unit of Vascular Surgery, IRCCS Policlinico San Donato, 20097 San Donato Milanese, Italy.

: Carotid artery stenosis (CAS) is one of the main causes of stroke, and the vulnerability of plaque has been proved to be a determinant. A joint analysis of shear wave elastography, a radiofrequency echo-based wall tracking technique for arterial stiffness evaluation, and of autonomic and baroreflex function is proposed to noninvasively, preoperatively assess plaque vulnerability in asymptomatic CAS patients scheduled for carotid endarterectomy. : Elastographic markers of arterial stiffness were derived preoperatively in 78 CAS patients (age: 74.

View Article and Find Full Text PDF

The aim of this study was to investigate the accuracy in fibrosis staging of a novel shear wave elastography (SWE) device (S-Shearwave Imaging by Samsung) and a previously validated 2D-SWE by Supersonic Imagine (SSI) in patients with biopsy proven metabolic dysfunction-associated steatotic liver disease (MASLD). This prospective study included 75 consecutive patients with MASLD who underwent liver biopsy for suspected MASH. All patients underwent S-Shearwave Imaging by Samsung and 2D-SWE with SSI on the same day of liver biopsy.

View Article and Find Full Text PDF

Diagnostic Accuracy of Shear Wave Elastography in Predicting Malignant Origins of Pleural Effusions in Emergency Departments.

Diagnostics (Basel)

January 2025

Odense Respiratory Research Unit (ODIN), Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, 5000 Odense, Denmark.

: Ultrasound is a valuable diagnostic tool in the diagnostic work-up of dyspnea and can identify even small pleural effusions. The incorporation of shear wave elastography (SWE) represents a possible tool in stratifying pleural effusions by the risk of underlying malignancy. No previous studies on ultrasound with the incorporation of SWE have been conducted in an emergency department (ED), where such stratification might have a clinical impact by hastening referrals for the diagnostic work-up of underlying malignancy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!