Background: Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is a frequently performed procedure. Suction is utilized during this procedure and may occasionally result in the collection of aspirated material, the diagnostic utility of which is uncertain. This study aims to determine the contents of the suction syringe aspirate and its diagnostic value.
Methods: The suction syringe aspirate was pooled in a container and sent for analysis. We retrospectively reviewed the cytological outcomes of these specimens in comparison to the diagnosis determined by EBUS-TBNA between 2015-2018. The primary outcome was the percent agreement between the diagnostic material found in the suction syringe aspirate, and the final diagnosis established by EBUS-TBNA.
Results: Forty-four patients were included. Percent agreement was calculated as the percent in which the suction syringe aspirate diagnosis agreed with the EBUS-TBNA diagnosis. The percent agreement of any diagnosis was 90.9% (95% CI: 78.7-97.2%). Two of the 44 diagnoses (4.5%) were established based solely on the suction syringe aspirate, both cases of granulomatous inflammation.
Conclusions: Our results suggest that material collected in the suction syringe has a very high percent agreement with the final diagnosis established by EBUS-TBNA. Furthermore, the suction syringe aspirate may represent the sole diagnostic material in nearly 5% of cases. Given the additional diagnostic material in the suction syringe aspirate, it is reasonable to pool the aspirate with the primary specimen in an effort to enrich the overall diagnostic specimen. This practice may improve the likelihood that the specimen will be sufficient for additional molecular analysis, although further study is necessary. Care must be taken when more than one needle is involved to ensure that a new suction syringe is also used to avoid inadvertent upstaging by specimen contamination.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6753429 | PMC |
http://dx.doi.org/10.21037/jtd.2019.08.55 | DOI Listing |
Objective: To describe indications for and demonstrate the technique to perform a transtracheal aspirate in horses. Transtracheal aspirate is indicated to collect samples for cytology and bacteriologic culture in cases of suspected pneumonia or other lower respiratory tract disease.
Animals: 1 healthy university-owned horse was used for demonstration purposes.
Respir Investig
January 2025
Department of Respiratory Medicine, Shizuoka Saiseikai General Hospital, Shizuoka City, Shizuoka, Japan.
Background: Coughing and other distress during bronchoscopy are undesirable for both patients and bronchoscopists. The efficacy of local anesthetics administered via aerosol sprays in the airways has been documented; however, the optimal administration method remains unclear. Furthermore, the efficacy of continuous salivary aspiration in reducing cough and other distress has not yet been evaluated.
View Article and Find Full Text PDFIndian J Otolaryngol Head Neck Surg
December 2024
Department of ENT, Head & Neck Surgery, Benazir Bhutto Hospital Rawalpindi, Rawalpindi, Pakistan.
To compare the efficacy of gel foam-soaked pyodine with a single topical application of clotrimazole ointment in the treatment of otomycosis. This randomized controlled trial included 90 patients who presented to ENT OPD with complaints of earache, watery ear discharge, pruritis, and ear blockage and were clinically diagnosed as a case of otomycosis via otoscopy. The external auditory canal of the patient was cleared of fungal debris via suction before treatment.
View Article and Find Full Text PDFWorld J Urol
September 2024
GRC n°20, Groupe de Recherche Clinique sur la Lithiase Urinaire, Hôpital Tenon, Sorbonne Université, 75020, Paris, France.
Purpose: To evaluate the stone clearance rate and limitations of a novel integrated suction capability within a single-use flexible ureteroscope according to stone particle size.
Methods: Varying sized stone particles were created using a stone phantom (Begostone Plus, Bego ©, Lincoln, RI, USA). Particle size ranged as follows: 63-125 µm, 125-250 µm, 250-500 µm, 500 µm- 1 mm and 1-2 mm.
Mikrochim Acta
August 2024
School of Chemistry and Pharmaceutical Sciences, State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Guangxi Normal University, Guilin, 541004, China.
An ultrasensitive photothermal assay was designed for point-of-care testing (POCT) of tumor markers based on a filter membrane. Firstly, CuSe was successfully encapsulated in liposome spheres with biotin on the surface and connected to carcinoembryonic antigen (CEA) aptamer with 3'end modified biotin by streptavidin. Secondly, the CEA antibody was successfully modified on the surface of the nitrocellulose membrane through simple incubation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!