Household air pollution (HAP) generated from solid fuel combustion is a major health risk. Direct measurement of exposure to HAP is burdensome and challenging, particularly for children. In a pilot study of the Household Air Pollution Intervention Network (HAPIN) trial in rural Guatemala, we evaluated an indirect exposure assessment method that employs fixed continuous PM monitors, Bluetooth signal receivers in multiple microenvironments (kitchen, sleeping area and outdoor patio), and a wearable signal emitter to track an individual's time within those microenvironments. Over a four-month period, we measured microenvironmental locations and reconstructed indirect PM exposures for women and children during two 24-h periods before and two periods after a liquefied petroleum gas (LPG) stove and fuel intervention delivered to 20 households cooking with woodstoves. Women wore personal PM monitors to compare direct with indirect exposure measurements. Indirect exposure measurements had high correlation with direct measurements (n = 62, Spearman ρ = 0.83, PM concentration range: 5-528 µg/m). Indirect exposure had better agreement with direct exposure measurements (bias: -17 µg/m) than did kitchen area measurements (bias: -89 µg/m). Our findings demonstrate that indirect exposure reconstruction is a feasible approach to estimate personal exposure when direct assessment is not possible.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7325654PMC
http://dx.doi.org/10.1038/s41370-019-0172-zDOI Listing

Publication Analysis

Top Keywords

indirect exposure
20
household air
12
air pollution
12
exposure measurements
12
exposure
9
personal exposure
8
measurements bias
8
indirect
7
direct
5
measurements
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!