The presence of endoleaks remains one of the main drawbacks of endovascular repair of abdominal aortic aneurysms leading to the increase of the size of the aneurysmal sac and in most of the cases to repeated interventions. A variety of devices and percutaneous techniques have been developed so far to prevent and treat this phenomenon, including sealing of the aneurysmal sac, endovascular embolisation, and direct sac puncture. The aim of this review is to analyse the indications, the effectiveness, and the future perspectives for the prevention and treatment of endoleaks after endovascular repair of abdominal aortic aneurysms.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6757092 | PMC |
http://dx.doi.org/10.1186/s13244-019-0774-y | DOI Listing |
Eur J Vasc Endovasc Surg
January 2025
Department of Vascular and Endovascular Surgery, General Hospital and Paracelsus Medical University, Nuremberg, Germany.
J Vasc Surg
January 2025
Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Boston, MA. Electronic address:
Objective: As aneurysmal disease is progressive, proximal disease progression and para-anastomotic aneurysms are complications experienced after open infrarenal abdominal aortic aneurysm repair (AAA). As such, fenestrated or branched endovascular repair (F/BEVAR) may be indicated in these patients. Data describing fenestrated endovascular aneurysm repair after prior open repair are limited to institutional databases.
View Article and Find Full Text PDFAnn Vasc Surg
January 2025
Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Emory University School of Medicine; Surgical and Perioperative Care, Atlanta VA Healthcare System. Electronic address:
Introduction: The higher prevalence of multiple chronic conditions and frailty among older adults may increase the physiologic demand required for wound healing after a major lower extremity amputation (LEA). After below knee amputations (BKA), patients generally have improved prosthetic fitting rates, postoperative ambulation, and quality of life compared to an above knee amputation (AKA). However, the benefit of a BKA must be weighed against the risk of wound complications.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
April 2025
Department of Radiology and Nuclear Medicine, University Teaching and Research Hospital Lucerne, Luzern, Switzerland.
Objective: The aim of this single-center case series is to demonstrate that an ultra-low dose (ULD) can be routinely achieved in the hybrid operating room in standard endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm by adjusting the manufacturer's predefined imaging parameters, hardware configurations and user protocols (including benchmarking).
Methods: The hybrid operating room manufacturer predefined EVAR software setup of the dose exposure control software (OPTIQ, Siemens Healthineers, Forchheim, Germany) at our university medical center was screened for possible improvements regarding radiation dose application. Tests on a water-equivalent as well as polymethyl methacrylate phantom model to assess the impact of technical settings were performed, including comparison of settings for exposure control software, different magnification, collimation configurations and detector distance.
BMJ Case Rep
January 2025
The Royal Melbourne Hospital, Parkville, Victoria, Australia.
Aortic angiosarcomas are extremely rare and difficult to diagnose. Here, we report a case of persistent pain and fever of unknown origin, culminating in the diagnosis of aortic epithelioid angiosarcoma at the site of a previous Dacron aortic graft.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!