The Diagnostic Value of Traditional Nasal Examination Tools in an Endoscopic Era.

Ear Nose Throat J

Department of Otorhinolaryngology, 37690Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.

Published: March 2021

Background: As the endoscope has become more common in the otolaryngologist's office, there is a need to reevaluate the value of traditional nasal examination methods. The objective of this study was to determine the sensitivity and specificity of traditional nasal examination tools compared to those of the rigid endoscope.

Methods: A prospective diagnostic study was conducted. Eligible patients with nasal symptoms were recruited and examined using 4 tools: (1) a nasal speculum, (2) an otoscope, (3) a posterior rhinoscopy mirror, and (4) a rigid nasal endoscope. The diagnostic value of each tool was evaluated.

Results: There were a total of 53 patients eligible for inclusion in the study. The mean age of all patients was 40.9 years. The most common nasal symptom was nasal obstruction (90.6%). With regard to the tools used in anterior rhinoscopy, the nasal speculum had a sensitivity of 54.69% (95% confidence interval [95% CI]: 41.75-67.18) and specificity of 88.10% (95% CI: 74.37-96.02); and the otoscope had a sensitivity of 57.81% (95% CI: 44.82-70.06) and specificity of 85.71% (95% CI: 71.46-94.57). After application of topical anesthesia and decongestant, the nasal speculum had a sensitivity of 67.19% (95% CI: 54.31-78.41) and specificity of 85.71% (95% CI: 71.46-94.57); and the otoscope had a sensitivity of 65.62% (95% CI: 52.70-77.05) and specificity of 83.33% (95% CI: 68.64-93.03). The posterior rhinoscopy mirror had a sensitivity of 12.50% (95% CI: 5.18-24.07) and specificity of 94.00% (95% CI: 83.45-98.75). All adverse events in this study were minor.

Conclusion: The traditional nasal examination tools exhibited excellent specificity. However, the sensitivity was only average, meaning that they may not be suitable for screening. We do not recommend routine use of topical anesthesia and decongestants when applying these tools, as the application of these agents did not improve the clinical sensitivity or specificity. The posterior rhinoscopy mirror had a lowest sensitivity. We thus do not recommend using a posterior rhinoscopy mirror to rule out pathologies of the posterior nasal cavity.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0145561319875711DOI Listing

Publication Analysis

Top Keywords

traditional nasal
16
nasal examination
16
posterior rhinoscopy
16
rhinoscopy mirror
16
nasal
12
examination tools
12
nasal speculum
12
95%
10
sensitivity
9
specificity
8

Similar Publications

Selective Detection of Formaldehyde and Nitrogen Dioxide Using Innovative Modeling of SnO Surface Response to Pulsed Temperature Profile.

Sensors (Basel)

December 2024

Laboratoire d'Analyse et d'Architecture des Systèmes (LAAS), Université de Toulouse, CNRS, UPS, 7 Avenue du Colonel Roche, 31031 Toulouse, France.

The need for odor measurement and pollution source identification in various sectors (aeronautic, automobile, healthcare…) has increased in the last decade. Multisensor modules, such as electronic noses, seem to be a promising and inexpensive alternative to traditional sensors that were only sensitive to one gas at a time. However, the selectivity, the non-repetitiveness of their manufacture, and their drift remain major obstacles to the use of electronic noses.

View Article and Find Full Text PDF

Nasal carcinomas in dogs are locally invasive neoplasms with a low metastatic rate that pose significant treatment challenges due to their location and aggressiveness. This study evaluates the safety, feasibility, and therapeutic outcomes of computed tomography-guided radiofrequency ablation (CT-guided RFA) in 15 dogs diagnosed with nasal adenocarcinoma. All patients underwent staging and histopathological diagnosis before treatment.

View Article and Find Full Text PDF

Introduction: Traditional extraocular electrical stimulation typically produces diffuse electric fields across the retina, limiting the precision of targeted therapy. Temporally interfering (TI) electrical stimulation, an emerging approach, can generate convergent electric fields, providing advantages for targeted treatment of various eye conditions.

Objective: Understanding how detailed structures of the retina, especially the optic nerve, affects electric fields can enhance the application of TI approach in retinal neurodegenerative and vascular diseases, an essential aspect that has been frequently neglected in previous researches.

View Article and Find Full Text PDF

Acupuncture Point Embedding Therapy is a comprehensive treatment method that combines modern biomaterials with acupuncture techniques. Acupoint catgut embedding (ACE) not only avoids the adverse reactions associated with Western medicine but also incorporates the benefits of traditional acupuncture, extending the duration of its therapeutic effects. Allergic rhinitis (AR) is a condition known for its challenging treatment and tendency to persist.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!