A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Multisensor System for the Characterization of the Field Pressure in Terrain. Accuracy, Response, and Adjustments. | LitMetric

In different disciplines of science, the knowledge of the resulting pressures in the subsoil can help to understand physical phenomena of mass exchange between the atmosphere and the terrain. The measurement of lower differential pressures is complicated given the low range of detected values. In this paper, a multisensor system has been designed and developed to measure differential pressures in radon gas transport studies. The adequacy of this system has been proven using a purpose-built pressure chamber and an automatic motion system developed by the authors. The temporal response frequencies, the pressure values measured by the sensors, and their ability to link in series were analyzed to offer a multisensor spatial and temporal mapping. At the same time, the influence of the components required for a real deployment were studied using different tube lengths and diameters, connectors, and obstructions across the operating range of the pressure sensors. The system has also been tested for measuring differential pressures in a real model with a concrete slab above the soil and a pressure generator system below. It was found that this system is very suitable for outdoor measurements that demand a quick temporal response and accuracy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6767342PMC
http://dx.doi.org/10.3390/s19183942DOI Listing

Publication Analysis

Top Keywords

differential pressures
12
multisensor system
8
temporal response
8
system
6
pressure
5
system characterization
4
characterization field
4
field pressure
4
pressure terrain
4
terrain accuracy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!