To unravel the underlying mechanisms of human balance control, system identification techniques are applied in combination with dedicated perturbations, like support surface translations. However, it remains unclear what the optimal amplitude and number of repetitions of the perturbation signal are. In this study we investigated the effect of the amplitude and number of repetitions on the identification of the neuromuscular controller (NMC). Healthy participants were asked to stand on a treadmill while small continuous support surface translations were applied in the form of a periodic multisine signal. The perturbation amplitude varied over seven conditions between 0.02 and 0.20 m peak-to-peak (ptp), where 6.5 repetitions of the multisine signal were applied for each amplitude, resulting in a trial length of 130 sec. For one of the conditions, 24 repetitions were recorded. The recorded external perturbation torque, body sway and ankle torque were used to calculate both the relative variability of the frequency response function (FRF) of the NMC, i.e., a measure for precision, depending on the noise-to-signal ratio (NSR) and the nonlinear distortions. Results showed that the perturbation amplitude should be minimally 0.05 m ptp, but higher perturbation amplitudes are preferred since they resulted in a higher precision, due to a lower noise-to-signal ratio (NSR). There is, however, no need to further increase the perturbation amplitude than 0.14 m ptp. Increasing the number of repetitions improves the precision, but the number of repetitions minimally required, depends on the perturbation amplitude and the preferred precision. Nonlinear contributions are low and, for the ankle torque, constant over perturbation amplitude.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TNSRE.2019.2943206DOI Listing

Publication Analysis

Top Keywords

number repetitions
20
perturbation amplitude
20
amplitude number
12
amplitude
9
perturbation
9
repetitions perturbation
8
system identification
8
human balance
8
balance control
8
support surface
8

Similar Publications

Background: The lifestyle intervention ProMuscle, which combines resistance exercise and an increased protein intake, was effective in improving muscle strength, muscle mass, and physical functioning in older adults. However, due to a growing shortage of health care professionals, the rapidly growing aging population cannot be personally guided in the future. Therefore, Uni2Move, a scalable web-based variant of ProMuscle, was designed to reach larger groups of older adults without putting additional burden on health care professionals.

View Article and Find Full Text PDF

Objectives: This study aimed to examine the relationship between marijuana use and aggression and victimization among Colombian adolescents. We aimed to clarify marijuana's distinct role by comparing different categories of drug use and by considering the order of drug initiation.

Methods: We conducted a secondary analysis of nationally representative cross-sectional data collected from Colombian adolescents in 2016.

View Article and Find Full Text PDF

Introduction: Inter-set rest intervals are essential to reduce muscle fatigue and increase the total amount of volume of resistance training. Static stretching and walking may increase muscle blood flow and promote recovery during inter-set rest intervals. Therefore, the purpose of this study was to investigate the effects of 20 seconds of static stretching and walking during inter-set rest intervals of leg extension exercises on the number of repetitions to exhaustion, total amount of volume, and flexibility of the quadriceps (joint range of motion and muscle hardness) in untrained healthy males.

View Article and Find Full Text PDF

Introduction: The one-minute sit to stand test (1min-STST) is a field test used to assess functional capacity. It is easily implementable and of significant clinical utility; however, no reference values are currently available for the Chilean population. The objective of this study was to establish reference values for the 1min-STST in a healthy Chilean population.

View Article and Find Full Text PDF

Chirp modulation can generate a relatively flat electro-optic frequency comb (EO comb) and offers the advantage of frequency reconfigurability, demonstrating significant potential in high-precision sensing and absorption spectroscopy measurements. However, nonresonant devices such as waveguides are susceptible to limitations in modulation efficiency and bandwidth during electro-optic modulation. In this paper, by utilizing chirp modulation resonance mode, we have realized an EO comb based on a lithium niobate resonator with small tooth spacing and high flatness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!