A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Feasibility study of utilizing XRV-124 scintillation detector for quality assurance of spot profile in pencil beam scanning proton therapy. | LitMetric

Purpose: The purpose of the current study is to (i) investigate the feasibility of utilizing the XRV-124 - a cone-shaped scintillation detector - to measure the spot size and spot position in pencil beam scanning proton therapy, and (ii) compare the spot sizes acquired by the XRV-124 with that of the widely used Lynx detector.

Methods: Spot position was tested by delivering a map of 30 spots at different locations to the XRV-124. Spot position test included energies 70-210 MeV. Spot size measurements were performed at the isocenter using the XRV-124 and Lynx detectors for a total of 32 energies (70-225 MeV at an increment of 5 MeV) at four cardinal gantry angles.

Results: The position (X, Y, and Z) of the radiation isocenter was within ±0.3 mm. For spots placed on the horizontal (X) and longitudinal (Y) axes of the spot map, both the X and Y locations of the spots were within ±0.5 mm. The spots placed diagonally in the map showed a higher deviation (±0.9 mm). In evaluating spot sizes acquired using the XRV-124 vs. Lynx, the results from the XRV were found to be slightly higher but within 0.2 mm for energies ≥130 MeV and within 0.4 mm for energies <130 MeV.

Conclusions: It is feasible to utilize the XRV-124 to perform the quality assurance of position and size of a pencil proton beam around the radiation isocenter but within the usable XRV-124 cone area.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2019.09.078DOI Listing

Publication Analysis

Top Keywords

spot position
12
xrv-124 lynx
12
spot
9
utilizing xrv-124
8
scintillation detector
8
pencil beam
8
beam scanning
8
scanning proton
8
proton therapy
8
spot size
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!