De Quervain syndrome is the second most common compressive tendinopathy. Although the length of the first extensor compartment (FEC) has been studied previously, there is no documented reported comparison study of short-axis and long-axis sonographic measurements. The thread technique, or Guo Technique, has been applied to carpal tunnel syndrome, trigger finger, and superficial peroneal compressive neuropathy. To perform this procedure, it is critically important to accurately identify the boundaries for transection. Twenty-one fresh frozen cadaver upper extremities were examined under ultrasound to determine the length of the extensor retinaculum (ER) over the FEC. Using the sonographic landmarks, the ERs were measured in short axis and long axis over their proximal to distal margins and from the distal margins to the distal edges of the radial styloids. These sonographic measurements were then compared with gross anatomical measurements. The short-axis sonographic measurement of the ER on average was 22.53 mm (95% confidence interval [CI] = 20.79-24.05 mm). The long-axis sonographic measurement of the ER on average was 15.65 mm (95% CI = 13.70-17.78 mm). The average length of the ER by gross anatomical dissection was 22.40 mm (95% CI = 21.15-23.51 mm). The short axis is not significantly different from the gross anatomical measurement; however, the long axis is significantly lower than the gross anatomical measurement. The results support the idea that the short axis is more accurate than the long axis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8461189PMC
http://dx.doi.org/10.1177/1558944719873435DOI Listing

Publication Analysis

Top Keywords

gross anatomical
16
short axis
12
long axis
12
extensor compartment
8
length extensor
8
long-axis sonographic
8
sonographic measurements
8
distal margins
8
margins distal
8
sonographic measurement
8

Similar Publications

Nowadays, consent to use donor bodies for medical education and research is obtained from the body donors and their families before the donation. Recently, the International Federation of Associations of Anatomists (IFAA) published guidelines that could restrict the appearance of cadaveric images in commercial anatomical resources such as textbooks and other educational products. These guidelines state that the donor must expressly consent to using such images for this purpose.

View Article and Find Full Text PDF

Gun-related violence is becoming increasingly more common in the United States, and ballistic injuries pose a challenge to the orthopaedic surgeon on trauma call. The guiding principles of trauma care are almost exclusively based on blunt trauma, and the management principles do not always translate. Ballistic long bone fractures, particularly of the lower extremity, can often be managed with similar principles, although the injury pattern can make restoration of anatomic alignment a challenge.

View Article and Find Full Text PDF
Article Synopsis
  • The study defines anatomical landmarks using preoperative MRI for patients with pituitary adenomas, focusing on how these landmarks relate to tumor resection rates and potential recurrence.
  • A review of 626 patients treated via endoscopic endonasal approach was conducted, categorizing anatomical landmarks and utilizing statistical analysis to create a predictive model for surgical outcomes.
  • Results showed a high gross total resection rate of 91.05%, identifying key anatomical landmarks and factors significantly associated with tumor progression, supported by a strong predictive model's accuracy.
View Article and Find Full Text PDF

Preclinical Experience Using 4D Intracardiac Echocardiography to Guide Cardiac Electrophysiology Procedures.

J Cardiovasc Electrophysiol

December 2024

Division of Cardiovascular Medicine, Cardiac Electrophysiology Section, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, USA.

Introduction: Intracardiac echocardiography (ICE) is an essential imaging modality for electrophysiology procedures, allowing intraprocedural monitoring, real-time catheter manipulation guidance, and visualization of complex anatomic structures. Four-dimentional (4D) ICE is the next stage in the evolution of the technology, permitting 360° rotation of the imaging plane, simultaneous multiplanar imaging, and volumetric acquisition, similar to transesophageal echocardiography (TEE). In this study, we report our experience with a novel 4D ICE catheter (NuVision, Biosense Webster) in structural electrophysiology procedures and difficult ventricular ablations in a swine preclinical model.

View Article and Find Full Text PDF

Purpose: As digital education is encroaching on the traditional method, it is important to get, the feedback of medical students. The current study has been proposed to investigate the perception of first-year MBBS students, regarding the use of 3D atlas for gross anatomy study as adjunct along with cadaveric dissection.

Methods: The feedback of 91 first-year MBBS students, regarding the incorporation of a 3D atlas in the dissection lab along with traditional cadaveric dissection was collected.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!